![Keysight Technologies N6900 Series Скачать руководство пользователя страница 250](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217250.webp)
Note that both Rise and Fall commands use the same resolution; which is determined by whichever
delay time (fall or rise) is the longest.
Parameter
Typical Return
0 - 1023, *RST 0
<delay value>
Sets a delay of 0.5 s before turning the output on: OUTP:DEL:RISE 0.5
l
Each APS model exhibits a minimum delay offset that applies from the time that a command to
turn on the output is received until the output actually turns on. If you specify a turn-on delay, this
delay will be added to the minimum delay offset, resulting in a turn-on delay that is actually longer
than the one you programmed.
l
Use OUTput:COUPle:MAX:DOFFset? to query the delay offset that is required for each instrument.
OUTPut:INHibit:MODE LATChing|LIVE|OFF
OUTPut:INHibit:MODE?
Sets the operating mode of the remote inhibit digital pin. The inhibit function shuts down the output in
response to an external signal on the Inhibit input pin. The Inhibit mode is stored in non-volatile
memory. See
LATChing - a logic-true signal on the Inhibit input causes the output state to latch OFF. The output
remains disabled until the Inhibit input is returned to logic-false and the latched INH status bit is
cleared by sending the OUTPut:PROTection:CLEar command or a protection clear command from the
front panel.
LIVE - allows the enabled output to follow the state of the Inhibit input. When the Inhibit input is true,
the output is disabled. When the Inhibit input is false, the output is re-enabled.
OFF - The Inhibit input is ignored.
Parameter
Typical Return
LATChing|LIVE|OFF
LATC, LIVE, or OFF
Sets the Inhibit Input to Live mode: OUTP:INH:MODE LIVE
OUTPut:PON:STATe RST|RCL0
OUTPut:PON:STATe?
Sets the output power-on state. This determines whether the power-on state is set to the *RST state
(RST) or the state stored in memory location 0 (RCL0).Instrument states can be stored using the *SAV
command. This parameter is saved in non-volatile memory.
Parameter
Typical Return
RST|RCL0
RST or RCL0
Sets the power-on state to the *RST state: OUTP:PON:STAT RST
Keysight N6900/N7900 Series Operating and Service Guide
250
6 SCPI Programming Reference
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...