![Keysight Technologies N6900 Series Скачать руководство пользователя страница 240](http://html1.mh-extra.com/html/keysight-technologies/n6900-series/n6900-series_operating-and-service-manual_1962217240.webp)
LIST Subsystem
List commands program an output sequence of multiple voltage or current settings. A comma-
delimited list of up to 512 steps may be programmed. Note that these commands only apply in the
presently active priority mode, either voltage priority or current priority.
[SOURce:]
LIST
:COUNt <
value
>|INFinity
Sets the list repeat count.
:CURRent
[:LEVel] <
value
>{,<
value
>} Specifies the setting for each list step.
:POINts?
Returns the number of list points.
:DWELl <
value
>{,<
value
>}
Specifies the dwell time for each list step.
:POINts?
Returns the number of list points.
:STEP ONCE|AUTO
Specifies how the list responds to triggers.
:TERMinate
:LAST 0|OFF|1|ON
Determines the output value when the list terminates.
:TOUTput
:BOSTep
[:DATA] <
Bool
>{,<
Bool
>} Generates a trigger out at the Beginning Of STep
:POINts?
Returns the number of list points.
:EOSTep
[:DATA] <
Bool
>{,<
Bool
>} Generates a trigger out at the End Of STep
:POINts?
Returns the number of list points.
:VOLTage
[:LEVel] <
value
>{,<
value
>} Specifies the setting for each list step.
:POINts?
Returns the number of list points.
[SOURce:]LIST:COUNt <
value
>|MIN|MAX|INFinity
[SOURce:]LIST:COUNt? [MIN|MAX]
Sets the list repeat count. This sets the number of times that a list is executed before it completes. The
count range is 1 through 4096. Infinity runs the list continuously.
Parameter
Typical Return
1 – 4096, *RST 1
<count>
Sets the list count to 10: LIST:COUN 10
Keysight N6900/N7900 Series Operating and Service Guide
240
6 SCPI Programming Reference
Содержание N6900 Series
Страница 1: ...Keysight Advanced Power System N6900 N7900 Series Operating and Service Guide...
Страница 2: ......
Страница 63: ...1 kW Models Keysight N6900 N7900 Series Operating and Service Guide 63 1 Quick Reference...
Страница 64: ...2 kW Models 1 Quick Reference 64 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 78: ...2 Installing the Instrument 78 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 90: ...Rack Mounting 2 Installing the Instrument 90 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 289: ...Status Diagram 6 SCPI Programming Reference 289 Keysight N6900 N7900 Series Operating and Service Guide...
Страница 354: ...Cover screws 8 Service and Maintenance 354 Keysight N6900 N7900 Series Operating and Service Guide...