N5990A M-PHY Station
2
System Configuration
M8020A Stand-alone
• To use this setup, select
M8020A
from the
Configuration
drop-down
and leave the
Separated Low Speed Generator
option unchecked.
• This system configuration only requires
M8020A
. The instrument works
as a Generator and as an Error Detector, if necessary.
• It supports three operation modes:
Loopback
,
Offline
and
Custom BER
mode, respectively.
• For
UniPro Test
mode, this configuration is not supported anymore due
to training pattern generation memory restrictions. This is described
below in DSGA.
DSGA
• To use this setup, select
M8020A
from the
Configuration
drop-down
and check the
Separated Low Speed Generator
option.
• This system configuration is recommended for the
UniPro
test mode. In
this case, the
DSGA
is used for the DUT configuration and to receive
the frame and error counters, while the
M8020A
is used to generate the
test pattern as well as the frame and error counter requests. If DUT
configuration must happen in the same lane, then that will be tested. It
is mandatory to use two switches to alternate the DUT inputs between
the two generators.
• The advantage of
M8020A
+
DSGA
setup with respect to the
standalone
M8020A
comes from the much lower
DSGA
data rate. Since
PWM
data with
M8020A
is generated by bit multiplication, and
depending on test conditions, the
M8020A
can run at 9,984 Gbps, the
generation of the training sequence takes much longer than the
DSGA
,
and the pattern may not even fit into the
M8020A
instrument's
memory.
• The
DSGA
Error Detector requires that the DUT responses come in
PWM
Mode, either
Bursted
or
Continuous
.
N4903B (stand-alone)
• To use this setup, select
JBERT
from the
Configuration
drop-down and
leave the
Separated Low Speed Generator
option unchecked.
• This system configuration only requires the
N4903B JBERT
. The
instrument works as Generator and as Error Detector, if necessary.
• It supports
Loopback,
Offline
and
Custom BER
operation modes. The
N4903B
stand-alone is not able to operate in
UniPro PHY
Test Mode
and has to be combined with
DSGA
.
Содержание N5990A
Страница 1: ...User Guide Keysight N5990A MIPI M PHY Receiver Test...
Страница 17: ...Keysight N5990A MIPI M PHY Receiver Test User Guide 1 Introduction Document History 18 Overview 19...
Страница 62: ......
Страница 86: ...86 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 88: ...88 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 214: ......
Страница 234: ......
Страница 268: ......
Страница 298: ......