N2784/5A User’s Guide

N2784/5A Probe Positioners

Contacting Keysight

The instructions in this section show you how to contact Keysight Technologies and 

how to properly package the instrument for return to a Keysight Technologies service 

office.

For technical assistance, contact your local Keysight Call Center.
- In the Americas, call 1 (800) 829-4444
- In other regions, visit http://www.keysight.com/find/assist

Before returning an instrument for service, you must first call the Call Center at 1 

(800) 829-4444

Returning the probe positioner for service

If the positioner is still under warranty or is covered by an maintenance contract, it 

will be repaired under the terms of the warranty or contract. If the positioner is no 

longer under warranty or is not covered by an maintenance plan, Keysight will notify 

you of the cost of the repair after examining the unit.

When an positioner is returned to an service office for servicing, it must be 

adequately packaged and have a complete description of the failure symptoms 

attached. When describing the failure, please be as specific as possible about the 

nature of the problem.

Please notify the service office before returning your positioner for service. Any 

special arrangements for the positioner can be discussed at this time. This will help 

the service office repair and return your instrument as quickly as possible. 

Preparing the instrument for shipping 

1

Pack the positioner. Use original packaging or comparable. Original materials are 

available through any Keysight office. Or, use the following guidelines:
- Wrap the positioner in anti-static plastic to reduce the possibility of damage 

caused by electrostatic discharge. 

- Use a double-walled, corrugated cardboard carton of 159 kg (350 lb) test 

strength. 

- The carton must be large enough to allow approximately 7 cm (3 inches) on all 

sides of the positioner for packing material, and strong enough to accommodate 

the weight of the positioner. 

- Surround the equipment with approximately 7 cm (3 inches) of packing material, 

to protect the instrument and prevent it from moving in the carton. If packing foam 

is not available, the best alternative is S.D-240 Air Cap™ from Sealed Air 

Corporation (Commerce, California 90001). Air Cap looks like a plastic sheet filled 

with air bubbles. Use the pink (anti-static) Air Cap™ to reduce static electricity. 

Wrapping the instrument several times in this material will protect the instrument 

and prevent it from moving in the carton. 

2

Seal the carton with strong nylon adhesive tape. 

3

Mark the carton “FRAGILE, HANDLE WITH CARE”. 

4

Retain copies of all shipping papers.

Содержание N2784A

Страница 1: ...Keysight N2784 5A Probe Positioner User s Guide...

Страница 2: ...ent EULA a copy of which can be found at http www key sight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify dis tribute...

Страница 3: ...N2784 5A User s Guide 3 Contents Contents Introduction 5 To Attach a Probe to the Positioner 7 Probe Angle Adjustment 9 Replacing the Probe Ties 11 Accessories 12 Contacting Keysight 14...

Страница 4: ...4 N2784 5A User s Guide Contents...

Страница 5: ...ysight scope probes including InfiniiMax single ended or differential browser probes as well as the scope probes from other vendors Figure 1 N2784A and N2785A Probe Positioners Compatible Probes The p...

Страница 6: ...5A User s Guide N2784 5A Probe Positioners Dimensions Figure 2 Height and length definitions Table 1 Dimensions and Weights Item Dimension Arm Length 320 mm Arm Height 158 mm Weight N2784A 850g N2785A...

Страница 7: ...the universal holders Align the probe with the rubber ribs Figure 3 Probe aligned with rubber ribs 2 Wrap the releasable probe tie around the probe head Figure 4 Probe tie wrapped around the probe 3 O...

Страница 8: ...8 N2784 5A User s Guide N2784 5A Probe Positioners Figure 5 Tightening the probe tie around the probe CAUTION Do not over tighten the probe tie or you could damage the probe...

Страница 9: ...obs are securely fastened during any measurements Knob 3 may be left loose when the probe is used vertically If the probe is to be used with some slope against the board then it must be tightened as w...

Страница 10: ...10 N2784 5A User s Guide N2784 5A Probe Positioners Figure 7 Series of pictures showing various rotation axes...

Страница 11: ...th the supplied probe ties To replace a probe tie loosen the screws labeled B in Figure 8 to unfasten the worn probe tie You can then replace the probe tie with a new one by reversing these steps You...

Страница 12: ...robe positioner s body during storage as shown in Figure 9 Figure 9 Using the arm strap to secure the positioning arms and universal holders The magnifying glass can be attached to the probe positione...

Страница 13: ...e universal holder placed on the probe rest Ordering Replacement Accessories To replace missing accessories order the N2785 68701 support kit The accessories included in this kit are Probe rest Magnif...

Страница 14: ...rvice Any special arrangements for the positioner can be discussed at this time This will help the service office repair and return your instrument as quickly as possible Preparing the instrument for...

Страница 15: ...N2784 5A Probe Positioners N2784 5A User s Guide 15...

Страница 16: ...This information is subject to change without notice Keysight Technologies 2019 March 2019 N2785 92002 www keysight com...

Отзывы: