150
Keysight M8070A Programming Guide
5
SCPI Command Reference
[:SOURce]:JITTer[:GLOBal][:STATe][?]
Syntax
[:SOURce]:JITTer[:GLOBal][:STATe] ‘identifier’, <ON|OFF|1|0>
[:SOURce]:JITTer[:GLOBal][:STATe]? ‘identifier’
Input
Parameters
‘identifier’: 'M1.System'
<ON|OFF|1|0>: Enable/disable global state.
Return Range
1|0
Description
This command enables or disables global jitter.
It is a global SCPI; working for all modules.
Example
:JITT:STAT ‘M1.System’, off
[:SOURce]:JITTer:CONFigure[:DELay][?]
Syntax
[:SOURce]:JITTer:CONFigure[:DELay] ‘identifier’, <NRf>
[:SOURce]:JITTer:CONFigure[:DELay]? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', ‘M1.ClkOut’, or 'M*.DataOut'
<NRf>: Set jitter profile delay.
Return Range
-40 ns to 40 ns
Description
Sets the delay of the jitter profile of the corresponding output.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
Example
:JITT:CONF:DEL ‘M1.DataOut2’, 2e-9
[:SOURce]:JITTer:CONFigure:HMODe[?]
Syntax
[:SOURce]:JITTer:CONFigure:HMODe 'Identifier', < ON | OFF | 1 | 0>
[:SOURce]:JITTer:CONFigure:HMODe? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut'
< ON | OFF | 1 | 0>
Return Range
1 | 0