SCPI Command Reference
Return Range
GAUS | RCOS
Description
This command specifies filter type used on the waveform. Depending upon
the specific waveform used, the waveform gets properties like transition
time or bandwidth limits.
This query returns the present setting.
This SCPI is applicable for M8196A.
Example
:PULS:FILT:TYPE ‘M1.DataOut2’, GAUS
[:SOURce]:PULSe:ROFFfactor[?]
Syntax
[:SOURce]:PULSe:ROFFfactor ‘identifier’, <NRf>
[:SOURce]:PULSe:ROFFfactor? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', 'M*.DataOut3', or 'M*.DataOut4'
<NRf>: Sets the roll-off-factor value. The value should be between 0 to 1.
Description
This command sets the roll-off factor for the raised cosine pulse shaping
filter. It is a measure for the excess bandwidth the waveform contains
beyond Nyquist bandwidth.
This query returns the present setting.
This SCPI is applicable for M8196A.
Example
:PULS:ROFF ‘M1.DataOut2’, 0.50
[:SOURce]:PULSe:DELay[?]
Syntax
[:SOURce]:PULSe:DELay ‘identifier’, <NRf>
[:SOURce]:PULSe:DELay? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', 'M*.DataOut3', or 'M*.DataOut4'
<NRf>: Set the pulse delay time.
Return Range
For M8041A: 0.0 ps to 100 ns
For M8195A: -1ns to 1ns
For M8062A: 0 ps to 100 ns
For M8045A: 0 ps to 100 ns