:SBUS<n> Commands
29
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
779
:SBUS<n>:I2S:TRIGger:PATTern:DATA
Command Syntax
:SBUS<n>:I2S:TRIGger:PATTern:DATA <string>
<string> ::= "n" where n ::= 32-bit integer in signed decimal when
<base> = DECimal
<string> ::= "nn...n" where n ::= {0 | 1 | X | $} when
<base> = BINary
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X | $} when
<base> = HEX
The :SBUS<n>:I2S:TRIGger:PATTern:DATA command specifies the I2S trigger data
pattern searched for in each I2S message.
Set a <string> bit to "0" or "1" to set the corresponding bit in the data pattern to
low or high, respectively.
Set a <string> bit to "X" to ignore (mask off) that bit in the data pattern.
Use the "$" character to indicate that the value of the corresponding bit will not be
changed (the existing bit value is used).
When <base> = DECimal, the "X" and "$" characters cannot be entered. When
queried, the "$" character is returned when any bits in the pattern have the value
of "X" and <base> = DECimal. When any bits in a given nibble have the value of "X"
and <base> = HEX, the "$" character is returned for the corresponding nibble.
NOTE
<base> is specified with the :SBUS<n>:I2S:TRIGger:PATTern:FORMat command. The default
<base> is DECimal.
NOTE
The :SBUS<n>:I2S:TRIGger:PATTern:DATA command specifies the I2S trigger data pattern
used by the EQUal, NOTequal, GREaterthan, and LESSthan trigger conditions. If the
GREaterthan or LESSthan trigger condition is selected, the bits specified to be masked off
("X") will be interpreted as 0's.
NOTE
The length of the trigger data value is determined by the :SBUS<n>:I2S:RWIDth and
:SBUS<n>:I2S:TWIDth commands. When the receiver word size is less than the transmitter
word size, the data length is equal to the receiver word size. When the receiver word size is
greater than the transmitter word size, the data length is equal to the transmitter word size.
NOTE
If more bits are sent for <string> than the specified trigger data length, the most significant
bits will be truncated. If the word size is changed after the <string> is programmed, the added
or deleted bits will be added to or deleted from the least significant bits.
Содержание InfiniiVision 3000T X Series
Страница 1: ...Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide...
Страница 40: ...40 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 1 What s New...
Страница 50: ...50 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Страница 64: ...64 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Страница 164: ...164 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 4 Commands Quick Reference...
Страница 254: ...254 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Страница 286: ...286 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 10 CHANnel n Commands...
Страница 306: ...306 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 12 DEMO Commands...
Страница 314: ...314 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 13 DIGital d Commands...
Страница 344: ...344 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 16 EXTernal Trigger Commands...
Страница 352: ...352 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands FFT WINDow on page 362...
Страница 364: ...364 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands...
Страница 402: ...402 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 18 FUNCtion m Commands...
Страница 420: ...420 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 19 HARDcopy Commands...
Страница 442: ...442 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 21 MARKer Commands...
Страница 466: ...466 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands MEASure CLEar on page 464...
Страница 524: ...524 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands...
Страница 548: ...548 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 23 MEASure Power Commands...
Страница 656: ...656 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 26 POWer Commands...
Страница 666: ...666 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 27 RECall Commands...
Страница 888: ...888 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 29 SBUS n Commands...
Страница 978: ...978 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 30 SEARch Commands...
Страница 1006: ...1006 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 32 TIMebase Commands...
Страница 1232: ...1232 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 37 Obsolete and Discontinued Commands...
Страница 1240: ...1240 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 38 Error Messages...
Страница 1264: ...1264 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 39 Status Reporting...
Страница 1274: ...1274 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 40 Synchronizing Acquisitions...
Страница 1404: ...1404 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 42 Programming Examples...