58
Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
2
Horizontal Controls
To position the time reference (left, center, right)
Time reference is the reference point on the display for delay time (horizontal
position).
1
Press
[Horiz]
.
2
In the Horizontal Menu, press
Time Ref
; then, select:
•
Left
— the time reference is set to one major division from the left edge of the
display.
•
Center
— the time reference is set to the center of the display.
•
Right
— the time reference is set to one major division from the right edge of
the display.
A small hollow triangle (
∇
) at the top of the display grid marks the position of the
time reference. When delay time is set to zero, the trigger point indicator (
▼
)
overlays the time reference indicator.
The time reference position sets the initial position of the trigger event within
acquisition memory and on the display, with delay set to 0.
Turning the Horizontal scale (sweep speed) knob expands or contracts the
waveform about the time reference point (
∇
Turning the Horizontal position (
) knob in Normal mode (not Zoom) moves the
trigger point indicator (
▼
) to the left or right of the time reference point (
∇
). See
"To adjust the horizontal delay (position)"
Searching for Events
You can use the
[Search]
key and menu to search for Edge, Pulse Width, Rise/Fall
Time, Runt, and Serial events on the analog channels.
Setting up searches (see
on page 59) is similar to setting up
triggers. In fact, except for Serial events, you can copy search setups to trigger
setups and vice-versa (see
Searches are different than triggers in that they use the measurement threshold
settings instead of trigger levels.
Содержание InfiniiVision 3000 X Series
Страница 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Страница 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 424: ...424 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 28 UART RS232 Triggering and Serial Decode...