I2C/SPI Triggering and Serial Decode
25
Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
385
SPI Serial Decode
To set up the oscilloscope to capture SPI signals, see
To set up SPI serial decode:
1
Press
[Serial]
to display the Serial Decode Menu.
2
Press the
Word Size
softkey; then, turn the Entry knob to select the number of
bits in a word.
3
Press the
Bit Order
softkey; then turn the Entry knob to select the bit order, most
significant bit first (MSB) or least significant bit first (LSB), used when
displaying data in the serial decode waveform and in the Lister.
4
If the decode line does not appear on the display, press the
[Serial]
key to turn it
on.
5
If the oscilloscope is stopped, press the
[Run/Stop]
key to acquire and decode
data.
You can use the horizontal
Zoom
window for easier navigation of the acquired data.
See Also
•
•
"Interpreting SPI Lister Data"
•
"Searching for SPI Data in the Lister"
NOTE
For SPI triggering setup see
NOTE
If the setup does not produce a stable trigger, the SPI signal may be slow enough that the
oscilloscope is AutoTriggering. Press the
[Mode/Coupling]
key, then press the
Mode
softkey
to set the trigger mode from
Auto
to
Normal
.
Содержание InfiniiVision 3000 X Series
Страница 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Страница 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 424: ...424 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 28 UART RS232 Triggering and Serial Decode...