Cursors
The Y1 cursor is the short-dashed horizontal line and the Y2 cursor is the
long-dashed horizontal line.
The Y cursors adjust vertically and typically indicate values relative to the
waveform's ground point, except math FFT where the values are relative to 0 dB.
In XY horizontal mode, the Y cursors display channel 2 values (Volts or Amps).
When active, the Y1 and Y2 cursor values for the selected waveform source are
displayed in the softkey menu area.
The difference between Y1 and Y2 (
Δ
Y) is displayed in the Cursors box in the
right-side information area.
To make cursor measurements
1
Connect a signal to the oscilloscope and obtain a stable display.
2
Press the
[Cursors]
key.
The Cursors box in the right-side information area appears, indicating that
cursors are "on". (Press the
[Cursors]
key again when you want to turn cursors
off.)
3
In the Cursors Menu, press
Mode
; then, select the desired mode:
•
Manual
—
Δ
X, 1/
Δ
X, and
Δ
Y values are displayed.
Δ
X is the difference
between the X1 and X2 cursors and
Δ
Y is the difference between the Y1 and
Y2 cursors.
•
Track Waveform
— As you move a marker horizontally, the vertical amplitude
of the waveform is tracked and measured. The time and voltage positions
are shown for the markers. The vertical (Y) and horizontal (X) differences
between the markers are shown as
Δ
X and
Δ
Y values.
•
Binary
— Logic levels of displayed waveforms at the current X1 and X2 cursor
positions are displayed above the softkeys in binary. The display is color
coded to match the color of the related channel's waveform.
Содержание InfiniiVision 3000 X Series
Страница 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Страница 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Страница 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Страница 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 24 FlexRay Triggering and Serial Decode...
Страница 424: ...424 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 28 UART RS232 Triggering and Serial Decode...