Installation 

Guide

Keysight E6640A/E6650A 

Rack Mount Kit 

This installation note contains procedures for 

installing the Rack Mount Kit for the Keysight 

E6640A/E6650A 18-slot PXIe Chassis in a standard 

EIA rack

Содержание E6640A

Страница 1: ...tallation Guide Keysight E6640A E6650A Rack Mount Kit This installation note contains procedures for installing the Rack Mount Kit for the Keysight E6640A E6650A 18 slot PXIe Chassis in a standard EIA rack ...

Страница 2: ...Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not re...

Страница 3: ...To receive the latest updates by email subscribe to Keysight Email Updates at the following URL http www keysight com find MyKeysight Information on preventing instrument damage can be found at www keysight com find PreventingInstrumentRepair Is your product software up to date Periodically Keysight releases software updates to fix known defects and incorporate product enhancements To search for s...

Страница 4: ...4 ...

Страница 5: ...m rack thermal efficiency place the instrument or chassis with the greatest power consumption towards the top of the rack This promotes efficient cooling since heat rises when placed nearer to the top of the rack high power instruments will not unnecessarily heat other instruments However in doing this do not violate the guideline that the heaviest instruments should be placed at the bottom of the...

Страница 6: ...from both sides of the M9018A PXIe chassis 2 Remove the four chassis feet by pulling out the small rubber insert on each foot and then removing the Phillips screw that attaches the foot to the chassis See the figure below Figure 1 Removing the chassis feet Do not stand the chassis on its side the side handles may cause the chassis to tip over ...

Страница 7: ...ide 7 Rack Mount Kit Installation 3 Attach the rack flanges p n E6640 00006 E6640 00007 to the chassis using the M4 0 screws p n 0515 2043 Figure 2 Attaching handles and rack mount flanges to the E6640A E6650A chassis ...

Страница 8: ...ack Mount Kit Installation 4 Attach the leveling slides to the underside of the chassis using the M4 0 flat head screws p n 0515 0896 Refer to the figure below Figure 3 Attaching leveling slides to the E6640A E6650A chassis ...

Страница 9: ...n the flanges on the rack s vertical columns where the chassis is to be mounted Align the adapter holes over the center holes of the EIA rack units Slide channel nuts over the rack holes to be used by the rack mount flanges See the figure below Figure 4 Center holes of EIA rack attaching channel nuts ...

Страница 10: ...le 8 Attach the support rails UPSIDE DOWN to the rack s inside vertical columns Use four channel nuts and the four 10 32 x 0 5 support rail to rack pan head screws as illustrated in the previous step 9 Install the instrument by setting the chassis onto the support rails INSTALL THE SUPPORT RAILS UPSIDE DOWN IN THE RACK To provide adequate air flow to the ventilation holes on the sides of the chass...

Страница 11: ...l the rack mount front handle flanges are against the rack s vertical columns Secure the chassis to the rack using the dress screws p n 0570 1577 provided with the rack flange kit If the rack will be moved excessively or over long distances you should use a strap to secure the chassis to the rack slides ...

Страница 12: ...This information is subject to change without notice Keysight Technologies 2014 2018 Edition 1 April 2018 E6640 90023 www keysight com ...