Options and Fuse Information
Ensure you order the proper instrument option for the mains power that will be used for the instrument.
Options 0EM, 0E3, and 0E9 determine which power-line voltage is selected at the factory. The default is configured
for 230 VAC ± 10%, 47-63 Hz input voltage (option 0E3).
Option
Description
0EM
115 VAC ± 10%, 47-63 Hz input voltage
0E3
230 VAC ± 10%, 47-63 Hz input voltage
0E9
100 VAC ± 10%, 47-63 Hz input voltage
Input power for E36102B, E36103B, E36104B, E36105B, and E36106B is 200 VA maximum.
Ensure the correct AC input voltage and fuse settings
Use the proper switch settings
To change the input AC voltage selector on the power supply, use the two AC selector switches on the underside of
the power supply as shown.
For example, to select 230 V, slide the left switch to the left and the right switch to the right, as illustrated in the
diagram below the switches.
To select 115 V, slide both switches to the right, and to select 100 V, slide the two switches towards each other.