Cursors
13
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
195
•
Hex
— Logic levels of displayed waveforms at the current X1 and X2 cursor
positions are displayed above the softkeys in hexadecimal.
Manual
and
Track Waveform
modes can be used on waveforms that are displayed
on the analog input channels (including math functions).
Binary
and
Hex
modes apply to digital signals (of MSO oscilloscope models).
In
Hex
and
Binary
modes, a level can be displayed as 1 (higher than trigger
level), 0 (lower than trigger level), indeterminate state ( ), or X (don't care).
In
Binary
mode, X is displayed if the channel is turned off.
In
Hex
mode, the channel is interpreted as 0 if turned off.
4
Press
Source
(or
X1 Source
,
X2 Source
in the
Track Waveform
mode); then, select
the input source for cursor values.
5
Select the cursor(s) to be adjusted:
•
Push the Cursors knob; then, turn the Cursors knob. To finalize your
selection, either push the Cursors knob again or wait about five seconds for
the popup menu to disappear.
Or:
•
Press the
Cursors
softkey; then, turn the Entry knob.
The
X1 X2 linked
and
Y1 Y2 linked
selections let you adjust both cursors at the
same time, while the delta value remains the same. This can be useful, for
example, for checking pulse width variations in a pulse train.
The currently selected cursor(s) display brighter than the other cursors.
6
To change the cursor units, press the
Units
softkey.
In the Cursor Units Menu:
Содержание DSO-X 2014A
Страница 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Страница 268: ...268 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 25 UART RS232 Triggering and Serial Decode...