Triggers
10
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
143
a
Press the
Arm A
softkey, and turn the Entry knob to select the channel on
which the arming edge will occur.
b
Press the
Slope A
softkey to specify which edge of the Arm A signal will arm
the oscilloscope.
c
Press the
Trigger B
softkey, and turn the Entry knob to select the channel on
which the trigger edge will occur.
d
Press the
Slope B
softkey to specify which edge of the Trigger B signal will
trigger the oscilloscope.
Adjust the trigger level for the selected analog channel by turning the Trigger
Level knob. Press the
[Digital]
key and select
Thresholds
to set the threshold level
for digital channels. The value of the trigger level or digital threshold is
displayed in the upper-right corner of the display.
5
Press the
Back/Up key to return to the Trigger Menu.
6
Press the
Delay
softkey; then, turn the Entry knob to enter the delay time
between the Arm A edge and the Trigger B edge.
7
Press the
Nth Edge B
softkey; then, turn the Entry knob to select the Nth edge of
the Trigger B signal to trigger on.
Pulse Width Trigger
Pulse Width (glitch) triggering sets the oscilloscope to trigger on a positive or
negative pulse of a specified width. If you want to trigger on a specific timeout
value, use
Pattern
trigger in the Trigger Menu (see
1
Press the
[Trigger]
key.
2
In the Trigger Menu, press the
Trigger
softkey; then, turn the Entry knob to
select
Pulse Width
.
Back
Содержание DSO-X 2014A
Страница 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Страница 268: ...268 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 25 UART RS232 Triggering and Serial Decode...