background image

Page 2

Find us at 

www.keysight.com

 

At a fraction of the cost of other  
standalone data acquisition systems

 

– 3-slot mainframe with built-in 6½ digit DMM and

 

– 8 switch and control plug-in modules

 

– Measures and converts 12 different input signals: 

temperature with thermocouples, RTDs and thermistors; dc/
ac volts; 2- and 4-wire resistance; frequency and period; dc/
ac current and capacitance

 

– LAN and USB for easy connectivity to your PC:

 

– Graphical Web interface for point and click monitor and 

control

 

– USB flash drive support to copy/log data in standalone 

applications

Features

Price and performance beyond compare

Go ahead and compare the Keysight Technologies, Inc. DAQ970A 
Data Acquisition System with other data acquisition systems 
currently available. You’ll find it hard to come up with a system 
that offers the powerful measurement performance, flexibility, 
connectivity options and ease of use of the DAQ970A—even in 
systems costing three to five times as much.

What can you expect from a data acquisition 
system that’s this affordable? Measurements you 
can trust

We took the measurement engine from our best-selling benchtop 
DMM and embedded it inside a 3-slot mainframe. You get the 
benefit of proven Keysight measurement performance, universal 
inputs with built-in signal conditioning, and modular flexibility, all 
in a low-cost, compact data acquisition package. The DAQ970A 
features 6½ digits (22 bits) of resolution, 0.004% basic dcV 
accuracy, and ultra-low reading noise. Combine that with scan 
rates of up to 450 channels/sec, and you’ve got the speed and 
accuracy you need to get the job done right the first time.

Built-in signal conditioning to get your job done

Whether you need to measure temperature, ac/dc volts, 
resistance, frequency, or current, the DAQ970A can handle it. 
The internal autoranging DMM directly measures 12 different 
functions, eliminating the need for expensive external signal 
conditioning. And our unique design allows complete per channel 
configurability for maximum flexibility and quick, easy set up. It’s 
like having an independent, high-performance DMM behind each 
channel.

Standard connectivity to the PC

The DAQ970A has built-in Gigabit LAN and USB 2.0. With the 
standard LAN connections you also get the added benefit of a 
graphical Web interface for easy configuration of measurements 
and monitoring of results using a standard Web browser.

Convenient data storage with USB flash drive

The DAQ970A also features a built-in USB memory port so that 
you can use a USB flash drive to collect data without being 
connected to a PC. Data can be logged directly to the USB 
flash drive, extending your instrument’s memory, or copied from 
internal memory for transfer to a computer in another location.

www.allice.de 

Allice Messtechnik GmbH 

Содержание DAQ970A

Страница 1: ...T E C HNI C A L O V E R V IE W Keysight DAQ970A Data Acquisition System www allice de Allice Messtechnik GmbH...

Страница 2: ...tioning and modular flexibility all in a low cost compact data acquisition package The DAQ970A features 6 digits 22 bits of resolution 0 004 basic dcV accuracy and ultra low reading noise Combine that...

Страница 3: ...tection and LAN lock out are also provided to limit access The graphical Web interface makes it easy to configure measurements set up and execute scans or trouble shoot your designs from anywhere on t...

Страница 4: ...tiation of the measurements 6 Measurement configuration menu to set parameters for measurements 7 Knob 8 Cursor navigation keypad Label Description 1 Slot identifier 100 200 300 2 External trigger inp...

Страница 5: ...A is easy to use for a multitude of data logging and monitoring applications either stand alone or with a computer Its flexible modular design makes it scalable from 20 to 120 channels and lets you ad...

Страница 6: ...r later uploading to a PC Or if you need even more memory the DAQ970A USB port can be used to log data directly to a USB flash drive or to copy the data from the reading memory without being connected...

Страница 7: ...are drivers that support C C Visual Basic Visual Studio LAN and USB on the DAQ970A and SCPI programming language make integration even easier The functionality you need We put a lot of thought into de...

Страница 8: ...rement switching and control capabilities to choose from Modules include both low frequency and RF multiplexers a matrix switch a general purpose switch and a multifunction module that includes digita...

Страница 9: ...ing errors are also listed separately in the module specifications section Temperature measurement accuracies include ITS 90 conversion errors The thermocouple accuracies include the reference junctio...

Страница 10: ...0 0006 0 0040 0 0006 0 0055 0 0006 0 0005 0 0001 0 0002 0 0001 300 V 0 0020 0 0020 0 0035 0 0020 0 0040 0 0020 0 0055 0 0020 0 0005 0 0001 0 0002 0 0001 Resistance2 7 100 0 0030 0 0050 0 0050 0 0060 0...

Страница 11: ...Hz 10 Hz 0 10 0 05 0 10 0 06 0 10 0 06 0 11 0 06 0 010 0 008 10 Hz 20 kHz 0 02 0 05 0 04 0 06 0 05 0 06 0 06 0 06 0 010 0 008 20 kHz 50 kHz 0 05 0 09 0 06 0 09 0 07 0 09 0 08 0 09 0 010 0 0012 50 kHz...

Страница 12: ...uple DAQ970A extended temp ranges Probe5 Ref junction DMM accuracy E 200 C to 150 C 1 4 C J 210 C to 150 C 1 6 C K 200 C to 100 C 1 7 C N 200 C to 100 C 2 C R 50 C to 300 C 2 9 C T 200 C to 100 C 1 7...

Страница 13: ...20 pF 50 pF Capacitance Lo Earth NA 150 pF 135 pF 80 pF 80 pF NA 80 pF Volt Hertz limit 10 8 10 8 10 8 10 8 10 8 10 10 10 8 Characteristics typical Other T C CRJ accuracy Switch life no load Unlimited...

Страница 14: ...ms max alarm sampling Latency 5 ms typical to DAQ970A alarm output Read write speed 95 s Max count 2 26 1 Totalize input 100 kHz max Rising or falling edge programmable min H or L time 5uS Signal leve...

Страница 15: ...N 275 275 907A Totalizer 240 240 Characteristics Nominal Data out of Memory FETCh of 50K readings Single channel DAQ970A over USB DAQ970A over LAN Readings 55000 s 120000 s Rdgs with timestamp 35000 s...

Страница 16: ...t Burden Voltage at Full Scale DC current range Burden voltage 1 A 0 0011 V 10 A 0 011 V 100 A 0 11 V 1 mA 0 11 V 10 mA 0 027 V 100 mA 0 27 V 1 A 0 7 V Characteristics Nominal Other A D linearity 0 00...

Страница 17: ...ion EN 61010 2 030 2010 1st Edition ANSI ISA 61010 2 030 82 02 03 First Edition ANSI UL 61010 2 030 First Edition CAN CSA C22 2 No 61010 2 030 First Edition Refer to Declaration of Conformity for curr...

Страница 18: ...rature Operating all cards 0 to 55 C all cards 40 to 70 C all cards 40 C to 80 RH Storage Humidity non condensing 1 Not recommended for connection to ac line without external transient suppression Up...

Страница 19: ...n 120 V switching The DAQM900A module is divided into two banks of 10 two wire channels each All 20 channels switch both HI and LO inputs thus providing fully isolated inputs to the internal DMM or an...

Страница 20: ...ls 22 Com Current Fuse Fuse Internal DMM input 4W sense Internal DMM input Current Reference junction sensor Channel switches Bank switch Shunt switches DAQM902A 16 Channel High Speed Multiplexer Scan...

Страница 21: ...rnal measurements except current are supported The module low connection is isolated from earth and can float up to 300 V DAQM903A 20 Channel Actuator General Purpose Switch SPDT Form C latching relay...

Страница 22: ...el RF Multiplexer 50 2 GHz bandwidth BNC to SMB adapter cables included The Keysight DAQM905A RF multiplexers offer broadband switching capabilities for high frequency and pulsed signals Use them to r...

Страница 23: ...allows great flexibility for a variety of sense and control applications It combines two 8 bit ports of digital input and output a 100 kHz gated totalizer and two 12 V or 24 mA analog outputs all on a...

Страница 24: ...e With 26 bits of resolution it can count events at full speed for nearly 11 minutes without an overflow Max count 226 1 Totalize input 100 kHz max Rising or falling edge programmable Signal level 1 V...

Страница 25: ...mensions To rack mount two instruments side by side order thelock link kit part number DAQA194A FG and flange kit part number DAQA191A FG To rack mount a single instrument order the adapter kit part n...

Страница 26: ...nnel Solid state multiplexer DAQM901A 20 Channel armature multiplexer DAQM902A 16 Channel reed multiplexer DAQM903A 20 Channel actuator general purpose switch DAQM904A 4 x 8 Two wire matrix switch DAQ...

Отзывы: