6
DDR2(+LP) Compliance Testing Methods of Implementation
Required Equipment and Software
In order to run the DDR2 automated tests, you need the following equipment and software:
•
The minimum version of Infiniium oscilloscope software (see the D9020DDRC DDR2(+LP) test
application release notes)
•
Use one of the following oscilloscope models:
•
Keysight DSO9000A-Series, DSO90000A-Series, and DSOX90000A/Q/Z/V-Series
Oscilloscopes with a minimum bandwidth of 8 GHz (recommended) for accurate
measurements. For faster speed grade devices, a minimum bandwidth of 13 GHz
bandwidth is recommended.
•
Keysight UXR Oscilloscopes
•
D9020DDRC DDR2(+LP) Compliance Test Application, version 1.27 or higher
•
RAM reliability test software
•
1169A, 1168A, 1134A, 1132A, or 1131A InfiniiMax probe amplifiers
•
N5381A or E2677A differential solder-in probe head, N5382A or E2675A differential browser
probe head, N5425A ZIF probe head with N5426A or N5451A ZIF tip accessories, E2678A
differential socketed probe head
•
Any computer motherboard system that supports DDR2 memory
• Keyboard, qty = 1, (provided with the Keysight Infiniium oscilloscope)
• Mouse, qty = 1, (provided with the Keysight Infiniium oscilloscope)
Below are the required licenses:
•
D9020DDRC DDR2(+LP) Compliance Test Application license
•
N5414A InfiniiScan software license
• E2688A Serial Data Analysis and Clock Recovery software license
• N5404A Deep memory option (optional)
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...