Single-Ended Signals Overshoot/Undershoot Tests
136
DDR2(+LP) Compliance Testing Methods of Implementation
AC Overshoot Test Method of Implementation
The Overshoot test can be divided into two sub-tests: Overshoot amplitude and overshoot area.
The purpose of this test is to verify that the overshoot value of the test signal within a user-specific
region is lower than or equal to the conformance limit of the maximum peak amplitude allowed for
overshoot test as specified in the JEDEC specification.
When there is an overshoot, the overshoot area is calculated based on the overshoot width. The
overshoot area should be lower than or equal to the conformance limit of the maximum overshoot
area allowed as specified in the JEDEC specification.
Signals of Interest
Mode Supported: DDR2, LPDDR2
Signal cycle of interest: READ or WRITE
Signal(s) of Interest:
• Data Signal OR
• Data Strobe Signal OR
• Address Signal OR
• Control Signal OR
• Data Mask Control Signal OR
• Clock Signal
Signals required to perform the test on the oscilloscope:
• Pin Under Test, PUT - any signal of interest, as defined above
Test Definition Notes from the Specification
Table 81
AC Overshoot Specification for Address and Control Pin
A0-A15, BA0-BA2, CS, RAS, CAS, WE, CKE, ODT
Parameter
Specification
DDR2-400
DDR2-533
DDR2-667
DDR2-800
Maximum peak amplitude allowed for overshoot area
0.5(0.9)
1
V
0.5(0.9)
1
V
0.5(0.9)
1
V
0.5(0.9)
1
V
Maximum overshoot area above V
DD
1.33 V-ns
1.0 V-ns
0.8 V-ns
0.66 V-ns
Table 82
AC Overshoot Specification for Clock, Data, Strobe and Mask Pins
DQ, (U/L/R)DQS, (U/L/R)DQS, DM, CK, CK
Parameter
Specification
DDR2-400
DDR2-533
DDR2-667
DDR2-800
Maximum peak amplitude allowed for overshoot area
0.5 V
0.5 V
0.5 V
0.5 V
Maximum overshoot area above V
DDQ
0.38 V-ns
0.28 V-ns
0.23 V-ns
0.23 V-ns
Содержание D9020DDRC
Страница 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Страница 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 40: ...1 Installing the DDR2 Compliance Test Application 40 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 134: ...6 Single Ended Signals VIH VIL Data Mask Tests 118 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 158: ...9 Single Ended Signals Overshoot Undershoot Tests 142 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 186: ...10 Differential Signals AC Input Parameters Tests 170 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 342: ...17 Command and Address Timing CAT Tests 326 DDR2 LP Compliance Testing Methods of Implementation ...
Страница 366: ...19 Calibrating the Infiniium Oscilloscope and Probe 350 DDR2 LP Compliance Testing Methods of Implementation ...