                                                                                  TA7004NT TimeAttendance Terminal User Manual V1.00 

 

 

reader);Compatible  with  card  readers  such  as 

Keyking, Motorola/INDALA, HID, etc. 

Communication 

TCP/IP, direct access to the LAN; 

RS485  bus,  a  single  bus  can  be  connected  to  127 

controllers,  data  transmission  distance  ≥   1200 

meters;  

communication rate: TCP: 100M; RS485: 9600 1,1, n 

Can  communicate  with  the  DPU3000  series 

controllers. 

Input/output 

Reader input 

C  type  electric  lock  relay  output,3A  contact 

current,12V DC,LED indicatation 

Exit button,sensor 

Protection 

Input  overcurrent  protection,  automatic  recovery 

when normal 

All inputs/outputs with voltage dynamic protection 

All  relay  outputs  with  transient  overvoltage 

protection 

Self-check 

Support 

OLED screen  

Highlight, orange, blue two-color display 

Power 

Voltage:12VDC;Currency<0.3A 

Environment 

Temperature-20℃~60℃,Humidity0~90% 

Dimension(mm)  89*89*20 

Weight 

150g 

Software 

Windows2000/XP/Win7/Win8  

 

1.4

 

Application Mode 

 

standalone, no external card reader 

Содержание TimeAttendance TA7004NT

Страница 1: ...User Manual Thank you for selecting Keyking products Please read this manual thoroughly before using TA7004NT TimeAttendance KEYKING GROUP LIMITED...

Страница 2: ...3 3 1 Clock setting 14 3 1 1 Edit Time 14 3 2 Card setting 14 3 2 1 Add Card 14 3 2 2 Delete Card 15 3 2 3 Delete All Cards 16 3 3 System 16 3 3 1 Language 16 3 3 2 Menu Password 17 3 3 3 Reader Setti...

Страница 3: ...TA7004NT TimeAttendance Terminal User Manual V1 00 II 4 3 Install on the wall Surface Without Back Box 25 Chapter 5 Trouble shooting 27...

Страница 4: ...can be displayed in the effective distance of the sensing area and it can enter and exit the own space It can independently control the two way access of a door The entrance and exit function can be a...

Страница 5: ...r access control Wiegand card reader with LCD display of company name and clock Wiegand 26 or Wiegand 34 signal can be output can be used with any Wiegand format access controller 2 With one exit butt...

Страница 6: ...65 days and the cardholder system that unlocks unauthorized holidays will automatically prevent 2 sets of temporary time groups Once the temporary date passes the system can automatically notify all c...

Страница 7: ...nput output Reader input C type electric lock relay output 3A contact current 12V DC LED indicatation Exit button sensor Protection Input overcurrent protection automatic recovery when normal All inpu...

Страница 8: ...TA7004NT TimeAttendance Terminal User Manual V1 00 5 outdoor with reader indoor with TA7004NT indoor with reader outdoor with TA7004NT Indoor outdoor indoor outdoor...

Страница 9: ...tion Details of Keypads No Mark Definition Output BIN No Mark Definition Output BIN 1 1 Digital 1 1 7 7 Digital 7 111 2 2 Digital 2 10 8 8 Digital 8 1000 3 3 Digital 3 11 9 9 Digital 9 1001 4 4 Digita...

Страница 10: ...e Terminal User Manual V1 00 7 2 2 Socket Fig 2 2 RJ45 connector through a standard cable as shown below Fig 2 3 J1 Power J2 Door bell J3 RS485 J4 TCP IP J5 Reader input J6 Exit sensor Aux J7 reader o...

Страница 11: ...Wiring note J1 Power Supply 12V DC 12V Positive GND Ground J2 Door Bell Normally J2 outputs open signal if bell is not pressed If door bell is used door bell is pressed and J2 will outputs close signa...

Страница 12: ...ton SEN Sensor GND Ground IN1 Aux input 1 IN2 Aux input 2 J7 Reader output 12V Positive Power supply D0 Wiegand output D1 Wiegand output LED LED indicator GND Negative power supply BUZ Buzzer J8 relay...

Страница 13: ...T can communicate via half duplex RS485 bus up to 1200m communication distance Terminals use series connection Please make sure power supply is in off state before do wiring This helps to avoid any da...

Страница 14: ...Point Ground If controller transmission line is with shielding or needs ground line then all controllers transmission line can be grounded in either controller Please note do not gather all metal sid...

Страница 15: ...TA7004NT TimeAttendance Terminal User Manual V1 00 12 Fig 2 8 Crossed cable to PC Fig 2 9 8 1 8 1...

Страница 16: ...he number 9 is the up key Menu structure is shown below Del Card Del All Card Language Reader setting Clock Setting Card setting System Initial Edit time Input or flash Input or flash Chinese Menu pas...

Страница 17: ...when enter the manage menu 2 Use button 3 or 9 to select add card 3 Press to enter register interface 4 Input a ten digits number or flash the card you want to register on TA7004NT the card number wi...

Страница 18: ...lete Card 1 Use button 3 or 9 to select card setting 2 Use button 3 or 9 to select Del Crard 3 Press to enter delte card interface 4 Input a ten digital number or flash the card you want to register o...

Страница 19: ...step 2 3 2 3 Delete All Cards Use Del All Cards to clear all cards 1 Use button 3 0r 9 to select card setting 2 Use button 3 0r 9 to select Del all card 3 press card cleared 3 3 System 3 3 1 Language...

Страница 20: ...ct system 2 Select Menu password 3 Press to enter menu password 4 Use the keypad to input 6 digits password and press to confirm User will have to input the password if he wants to enter manage menu 3...

Страница 21: ...ystem 2 Select system info 3 Press to enter interface 4 Use button 3 or 9 to select Device ID and press to confirm Device ID Network Sleep Time Board Info Language Menu password Reader setting System...

Страница 22: ...se button 3 or 9 to enter system 2 Select system info 3 Use button 3 or 9 to select network 4 Unlock means IP can configure lock means IP cannot be changed special means 10 1 1 10 3 3 4 3 Sleep time 1...

Страница 23: ...on and production date Example Version TA7003 Ver 03 00 Date 20100415 Programmed date 2010 4 15 IP Address 192 168 1 100 MAC Address 0010F0040413 3 4 Initial 3 4 1 Clear event 1 Use button 3 or 9 to s...

Страница 24: ...ar card 3 4 3 Doorpara Init 1 Use button 3 or 9 to select initial 2 Select door parament initial 3 Press to initial the parament Clear Event Clear card Door para init Clear All Clock Setting Card Sett...

Страница 25: ...004NT 3 10cm read range 3 The screen shows card number owner name 4 Relay responds door open Please note that if the card is not registered the TA7003NT will beep three short sounds and shows invalid...

Страница 26: ...Box single b Reader Back Box Double 2 Route Route the interface cable from the reader to the Host 3 Wiring Install all wires to the green connector according below image 4 Plug the Green Connector Pl...

Страница 27: ...ll Determine an appropriate mounting position for the reader Install a single or double standard electrical box 86 86mm on the wall using 4 screws a Reader Back Box Surface Standard Electronic Box sin...

Страница 28: ...he reader body Mount the reader body to the Electronic Box Reader Back Box using Two 6 32 x 1 inch screws 7 Put the top cover and face plate 4 3 Install on the wall Surface Without Back Box 1 Drill a...

Страница 29: ...the green connector according below image 4 Plug the Green Connector Plug the green connector to the reader socket 5 Set the JUMPER Output mode select W26 or W34 bits output of reader 6 Mount the read...

Страница 30: ...mode Set to Card not Card PIN 5 Set door open mode as Card PIN in normal state but can not open the door by card PIN Invalid card register your card Wrong password Check password or set a new one Pre...

Отзывы: