TA7004NT TimeAttendance Terminal User Manual V1.00
23
Chapter 4 Installation
4.1
Install in the wall (based on Internal back box)
1.
Install a Reader Back Box inside wall: Determine an appropriate mounting
position for the reader. Install a single or double standard electrical box
(86*86mm) inside wall.
a). Reader Back Box (Standard Electronic Box, single)
b). Reader Back Box (Double)
2.
Route: Route the interface cable from the reader to the Host.
3.
Wiring: Install all wires to the green connector according below image.
4.
Plug the Green Connector: Plug the green connector to the reader socket.
5.
Set the JUMPER (Output mode): select W26 or W34 bits output of reader.
6.
Mount the reader body: Mount the reader body to the Electronic Box (Reader
Back Box) using the two screws. Two #6-32 x 1 inch screws are provided for
mounting to a gang box or metal surface.
7.
Put the top cover and face plate.