KEYKING GROUP LIMITED
TA7003NT User Manual
(
V1.0
)
Page 9 of 29
Icon
NO
Connection
Definition
Icon
NO
Connection
Definition
J1
1
GND
Power supply
J6
17
BUT
Magnetic, Rex
Button,
Auxiliary output
2
12V
18
SEN
J2
3
BELL
Door bell
19
GND
4
BELL
20
IN1
J3
5
485-
485 interface
21
IN2
6
485+
22
GND
J4
7
RX-
TCP/IP
interface
J7
23
12V
Reader signal
output
8
RX+
24
D0
9
TX-
25
D1
10
TX+
26
LED
J5
11
12V
External
reader
interface
27
GND
12
D0
28
BUZ
13
D1
J8
29
NC1
Relay output
14
LED
30
COM1
15
GND
31
NO1
16
BUZ
32
NC2
33
COM2
34
NO2
2-1
Wiring Description
:
J1: Power Supply
12V
:
DC 12V Positive
GND
:
Ground
J2: Door Bell
Normally, J2 outputs open signal if
is not pressed.
If door bell is used,
is pressed and J2 will outputs close signal to drive door bell rings.
J3: 485 Interfaces
An IC232 or RS485HUB is needed to connect host PC.
Customer can set all configurations when it’s connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J4: TCP/IP Interfaces
Available to use a switch or directly connect to host PC via Ethernet port.
Customer can set all configurations when it’s connected to host PC. Moreover user
authorization and exporting card events can also be done via AccessWatch3000.
J5: External Reader Interfaces
12V
:
External reader power supply (Positive)
D0
:
Wiegand input
D1
:
Wiegand output
LED: Indicator connector
GND
:
Ground.