Press # again to confirm Clear Card. 

3.4.3 Door Parameter Initialize 

1. Use button 3 or 9 to select Delete when enter the manage menu

.

 

 

2. Press # to enter Delete interface and use button 3 or 9 to select DoorPara Init. 

                        

 

Press # again to confirm Door Parameter Initialize. 

3.4.4 Clear All 

            If somehow the entire data, time, password or work mode is messed up, we can use Clear All to 

reset the controller to defaulted state.   

1. 

Use button 3 or 9 to select Delete when enter the manage menu

.

 

                                  

 

2. Press # to enter Delete interface and use button 3 or 9 to select Clear All. 

                        

 

        Press # again to confirm Clear All and all configuration will be set to defaulted.   

3.5 Door Open Mode 

1

 

By Card 

Steps: 1. Register your card by using Add Card in the manage menu. 2. Flash the card on TA7003NT. 

(3-10cm read range) 3. The screen shows card number, owner name. 4. Relay responds, door open.N 

Clear Event 

Clear Card   

DoorPara Init             

Clear All                

            

 

 

Clock               

Cards               

System 

Delete                

 

 

Clear Event 

Clear Card   

DoorPara Init            

 

Clear All               

 

 

Clock               

Cards               

System 

Delete                

 

 

Clear Event             

Clear Card 

            

            

DoorPara Init

 

Clear All 

 

     

 

 

Содержание TA7003NT

Страница 1: ...User Manual Thank you for selecting Keyking products Please read this manual thoroughly before using TA7003NT Time Attendance Standalone KEYKING GROUP LIMITED...

Страница 2: ...nfiguration 15 3 1 1 Edit Time 15 3 1 2 Edit Alarm 15 3 2 Card Configuration 16 3 2 1 Add Card 16 3 2 2 Delete Card 17 3 2 3 Del All Cards 17 3 3 System Configuration 18 3 3 1 Language Setting 18 3 3...

Страница 3: ...eir special space by flashing authorized cards TA7003NT can by itself control a door both in and out at least one reader is needed for one side and the other side can be controlled either by a reader...

Страница 4: ...IN 4 Customized OLED LOGO display English menu with backlight Showing the name and card number when reading a card 5 Network 127 for RS485 no limit for TCP IP offline mode available but customers need...

Страница 5: ...IN interval time 8 sec Supported User Number 30000 pcs PIN User Number 10 Communicate Frequency 125KHZ E EM 13 56MHZ M Mifare U CPU Read Range 3 15CM Outputs NC NO 30VDC 5A Power Supply 12VDC 10 200MA...

Страница 6: ...KEYKING GROUP LIMITED TA7003NT User Manual V1 0 Page 6 of 29 Indoor external reader outdoor TA7003NT Indoor TA7003N Outdoor reader Indoor Reader Outdoor TA7003N...

Страница 7: ...ndicator Green LED Sensor indicator Relay turned on indicator Keypad NO Key Description NO Key Description 1 1 Numeral 1 7 7 Numeral 7 2 2 Numeral 2 8 8 Numeral 8 3 3 Numeral 3 9 9 Numeral 9 4 4 Numer...

Страница 8: ...8 of 29 2 2 Wiring Diagram Figure 2 2 Backside TCP IP interface as shown below Figure 2 3 J7 Reader signal output J2 Door bell J4 TCP IP interface J6 Megnetic Rex Button Auxiliary output J5 Reader in...

Страница 9: ...Ground J2 Door Bell Normally J2 outputs open signal if is not pressed If door bell is used is pressed and J2 will outputs close signal to drive door bell rings J3 485 Interfaces An IC232 or RS485HUB...

Страница 10: ...side GND Negative Public side IN1 Auxiliary input 1 IN2 Auxiliary input 2 J7 Built in Reader Output 12V Positive D0 Wiegand output 0 D1 Wiegand output 1 LED Indicator connector GND Negative Public si...

Страница 11: ...isted pair Twisted pair are used to connect controller to controller No GND is needed Series connection Terminals are connecting via series connection A multi bus RS485HUB is needed if customer needs...

Страница 12: ...G GROUP LIMITED TA7003NT User Manual V1 0 Page 12 of 29 Figure 2 8 TCP IP crystal head Figure 2 9 Sheet 2 2 Normal net cable to switch 2 10 Crossed cable to PC RJ45 NO Difination 1 TX 2 TX 3 RX 6 RX 8...

Страница 13: ...KEYKING GROUP LIMITED TA7003NT User Manual V1 0 Page 13 of 29 Figure 2 11 8 1 8 1...

Страница 14: ...Chapter3 Instructions User Management PIN management Work mode and Time set are configured in the manage menu Menu structure is shown below Press 39 to enter manage menu when idle In the main menu wo...

Страница 15: ...3 works as Up 9 works as down 2 Press to edit time 3 Use keypad to set the current time press to confirm Time format Year Month Day Hour Minute 3 1 2 Edit Alarm 1 Press 39 to enter manage menu when i...

Страница 16: ...flash the card you want to register on TA7003NT the card number will be read by TA7003NT automatically and shows up on the screen 5 Press to enter the next menu Verify the card information and input...

Страница 17: ...automatically and shows up on the screen 5 Press to enter the next menu Note When the screen shows Del Card OK it means you have successfully deleted a registered card If customer wants to delete more...

Страница 18: ...nd shows up on the screen 5 Press to enter the next menu 3 3 System Configuration 3 3 1 Language Setting TA7003NT support two languages English and Chinese 1 Use button 3 or 9 to select System when en...

Страница 19: ...2 Use button 3 or 9 to select Menu Password 3 Press to enter Menu Password setting interface Use the keypad to input 6 digits password and press to confirm User will have to input the password if he...

Страница 20: ...ton 3 or 9 to select System Info 3 Press to enter System Info setting interface 4 Use button 3 or 9 to select Device ID and press to confirm Press to confirm Device ID setting Device ID must be set wh...

Страница 21: ...se button 3 or 9 to select network mode The defaulted IP address is 10 1 1 10 3 3 4 3 Sleep Time 1 Use button 3 or 9 to select System when enter the manage menu 2 Use button 3 or 9 to select System In...

Страница 22: ...date 2010 4 15 IP Address 192 168 1 100 MAC Address 0010F0040413 3 4 Delete 3 4 1 Clear Event 1 Use button 3 or 9 to select Delete when enter the manage menu 2 Press to enter Delete interface Press ag...

Страница 23: ...er to defaulted state 1 Use button 3 or 9 to select Delete when enter the manage menu 2 Press to enter Delete interface and use button 3 or 9 to select Clear All Press again to confirm Clear All and a...

Страница 24: ...ows invalid card on the screen Door will stay closed 2 By card PIN Steps 1 Register your card and set password by using Add Card in the manage menu Password is limited to 4 digits 2 Flash the card on...

Страница 25: ...where you want to install your reader Then install the installation box in the hole a Installation box Standard 86 box single b Installation box double 2 Wiring Design the wiring between reader and c...

Страница 26: ...se 4 screws to fix standard 86 box on the wall a Installation box Standard 86 box single 2 Wiring Design the wiring between reader and controller then process wiring 3 Connection Please refer to chapt...

Страница 27: ...30mm drill tool b Hole diameter 30mm Note This tool is used for metal and wooden wall no good for stone or cement wall 2 Wiring Design the wiring between reader and controller then process wiring 3 Co...

Страница 28: ...de Set to Card not Card PIN 5 Set door open mode as Card PIN in normal state but can not open the door by card PIN Invalid card register your card Wrong password Check password or set a new one Press...

Страница 29: ...d card registration events as per attached form when using Card Card PIN mode This will help to make a good management if customer wants to register a card or delete a card Card User Records NO Name C...

Отзывы: