You MuST use the Power Supply provided with your unit or you VOID the Key Digital

®

 Warranty 

and risk damage to your unit and associated equipment.

Mechanical

CE and RoHS compliant
Rack Mountable 1U
Dimensions: 17” X 7.5” X 1.75”
Weight: 6 Lbs. (excluding power supply)
Enclosure: Black Metal
Power Supply: 6V DC @ 6.6Amp (110-240V input 50/60Hz)

How to Contact Key Digital

®

Repairs and Warranty Service

Should your product require warranty service, please contact Key Digital

®

 to obtain a Returned 

Materials Authorization (RMA) number
Please contact us at either:

Phone: 

1-914-667-9700

E-mail: 

[email protected]

  

Technical Support

For technical questions about using our products, please contact us at either: 

Phone: 

1-914-667-9700

E-mail: 

[email protected]

  

Customer Support

For customer support questions about using our products, please contact us at either: 

Phone: 

1-914-667-9700

E-mail: 

[email protected]

  

Warranty

All Key Digital

®

 products are built to high manufacturing standards and should provide years of 

trouble-free operation.  They are backed by a limited two-year parts and labor warranty.

Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s 
instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other 
apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 
has two blades with one wider than the other. A grounding type plug has two blades and 
a third grounding prong. The wide blade or the third prong are provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.
  Protect the power cord from being walked on or pinched particularly at plugs, convenience 

receptacles, and the point where they exit from the apparatus.

 Only use attachments/accessories specified by the manufacturer.
 Unplug this apparatus during lightning storms or when unused for long periods of time.
  Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as power-supply cord or plug is damaged, liquid has 
been spilled or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

1.
2.
3.
4.
5.
6.
7.

8.

9.

10.

11.
12.
13.

Important Safety Instructions.

Please be sure to follow these instructions for safe operation of your unit

KD-MSV8x8_Manual.indd   12-13

8/30/07   3:55:29 PM

Содержание KD-MSV8X8

Страница 1: ...total video system solutions because we know and help drive the technology the industry the business and all the latest up and coming standards But most of all we know exactly what you need for your unique application the right solution Rev 0 Sept 2007 The KD MSV8X8 is a full matrix video switcher capable of integrating up to 8 inputs or sources with 8 outputs or zones The unit directly accepts co...

Страница 2: ... Begin with the KD MSV8X8 and all input output devices turned off with power cables removed Connect video sources to appropriate input ports on the KD MSV8X8 Connect video outputs to display or receiving devices Connect power to the KD MSV8X8 as well as all other input and output devices and turn them on Operate KD MSV8X8 switcher via front panel buttons IR remote serial IR or RS 232 control 1 2 3...

Страница 3: ...or VGA RGBHV 4 or Composite 8 S Video 8 RGBHV signals accommodated using two input ports and two output ports thereby creating a 4X4 RGBHV matrix switcher S Video signals accommodated with the use of S Video to Composite video adapter cables Additional Key Features Front panel LED input output assignment confirmation Easily controlled via IR remote included with discrete codes Serial IR and RS 232...

Страница 4: ...operation See page 11 5 Power Connection 6 RS 232 Connector a This connector has two functions It serves as a serial communication port for connection to RS 232 based control systems and also for firmware updates via serial connection to a standard PC See page 9 for RS 232 control protocol and page 12 for firmware update procedure Front Panel Features 1 Input select button a Press this button to c...

Страница 5: ...n the following manner 3 Press the number keypad buttons 01 08 to select the desired output to switch Note that the LED s will flash indicating selected output 4 Then press the number keypad buttons 01 08 to select the desired input Note that the LED s will change indicating selected input For all IR commands the steps 1 and 2 above must be issued first to address the unit See the following button...

Страница 6: ...mmand line SPCA02 Pin 2 Transmit Pin 3 Recieve Pin 5 Ground 3 Fade to Black Interval Set SP Oxx MI yy Oxx the letter O followed by the number Zero then xx This feature is for seemless switching When a switching command is issued the unit will fade the current input to black then switch then fade the new input back to normal level The fade times specified below are for this entire fade out switch f...

Страница 7: ...Follow the detailed directions carefully Firmware Update Procedure Check our web site at www keydigital com for the latest firmware update ZIP file Download and unzip the firmware ZIP file to any directory on the PC All of the unzipped files that are created must be located in same directory on the PC Be sure power to the unit is off The power button on the rear panel must be out or off to have a ...

Страница 8: ...his apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wid...