background image

Accessories

Part names

Preparation

Features

Polishing Procedure

Others

 

Open/close of the lever is linked with the motor

  When the lever is pushed, the polished sample will be 

ejected to the polished sample receptacle.

 

Sample scatter-proof function

  To avoid scattering of the sample, the polishing disk will 

not be rotated if the cover is fully opened.

 

Transparent bran receptacle

  The timing for discarding the removed bran can be seen 

at a glance.

 

Motor overload prevention

  If excessive force is applied to the motor and there is a 

risk of the motor coil being damaged, the power turns off 

automatically.

 

Properly attach the bran receptacle to the main unit.

  Fully insert the bran receptacle to the outlet of the 

removed bran. Note that if the case is not properly 

attached, the bran will be scattered during polishing.

 

Take a spoonful of sample with the supplied spoon.

*   A spoonful of rice measured with the supplied spoon is approxi-

mately 10 g.

 

Set the sample on the polishing disk of the 

Pearlest and close the cover. Then, lock the latch.

*   If bran or dust is left, the cover may not be closed. Before start 

polishing, clean the unit and fully close the cover.

 

Turn the power ON to start polishing.

  The polishing time differs depending on the samples or moisture 

content. Set the polishing time referring to the following.

Samples

A guide for polishing time

Short rice

30 to 40 sec.

Long rice

40 to 60 sec.

Barley

180 to 240 sec.

*   Many broken particles may be generated depending on the sample.
*   For barley, optional parts for barley polishing are required. Before 

polishing, refer to the back page and assemble the parts correctly.

 

Push the lever while the cover is closed.

*   If the sample is left in the polishing unit, the clatter may be heard.

  Push the lever until the sound is stopped.

 

The polished sample is ejected to the polished 

sample receptacle.

 

The motor stop when the power is turned off.

 

Open the cover, and take out the polished sample 

receptacle.

*   The polished sample receptacle can be used as a strainer. If bran 

or dust is left on the tray, clean the tray before use.

Pallet

(TP-3000-A-01)

Brush

(TP-3000-A-02)

AC adapter

(TP-3000-A-05)

Accessory case

(TP-3000-A-06)

Paint brush

(TP-3000-A-03)

Spoon

(Rice : approx. 10 g/spoon)

(TP-3000-A-04)

<Cleaning>

  After a few times of polishing, removed bran or dust may 

accumulate around the rubber disc or polishing disk. 

Clean the polishing unit using the pallet or paint brush.

<Storage>

  When storing the instrument, remove the polishing disk, 

rubber ring, and rubber disc.

  Clean the inside of the bran receptacle. Store the 

instrument in a place where the direct sunlight is avoided 

under dry conditions.

<Specifications>

 Power 

  Input: 100-240 V AC (50/60Hz), 1.4 A MAX

    Output: 24 V DC, 2.71 A

  Dimensions: 110 (W) x 152 (D) x 176 (H)

  Mass: approximately 1.7 kg

Compact Grain Polisher Pearlest

TP-3000 

Operating Manual

Thank you for purchasing our grain polisher.

The Compact Grain Polisher Pearlest can polish a 

small amount of rice extracted for the purpose of 

testing in a short time. Since the rubber plate is used, 

capability of bran removal is excellent, and the grains 

are well finished. The polished grains can be ejected 

only by pushing the motor-linked lever. The Pearlest 

can also be used for inspecting condition and mixing 

degree  of  spotted  rice  influenced  by  pentatomid, 

burnt, cracked, colored, nonglutinous, or glutinous 

rice. Before using this instrument, thoroughly read 

this operating manual, and use it properly.

Bran receptacle

(TP-3000-R-04)

Power switch

Cover

Latch

Lever

(TP-3000-R-06)

Rubber disc

(TP-3000-R-05)

Polished sample receptacle

(TP-3000-R-01)

Rubber ring

(TP-3000-R-02)

Polishing disk

(TP-3000-R-03)

Status lamp
Timer jack
DC power inlet

 

Make sure that the cover is closed, and the power 

is turned off. When the AC adapter is connected to 

the outlet, the status lamp will light up.

(1) Push the bottom part 

of the bran receptacle 

toward the main unit.

(2) Pull the entire case 

from the top.

<How to remove>

*   Do not put the fingers into the outlet of the removed bran. 

The drive unit can catch fingers and severely injure them.

  Status lamp

<On>  The device is ready to be used.
<Off>   For safety, the sensor is activated and the device is 

stopped.

 

 Close the cover while the AC adapter is connected to the 

outlet. When the POWER switch is turned off, the status 

lamp will be lit to indicate the device is ready to be used.

<Blink>   Due to over-current, the device is stopped protecting the 

motor.

 

 If the lamp is blinking while the AC adapter is connected to 

the outlet, disconnect the plug once, and reconnect. If 

blinking or off state continues, contact Kett.

*   Do not use other than the specified AC adapter.  

Otherwise, it may cause malfunction, fire, or electric 

shock, etc.

Содержание Pearlest

Страница 1: ...lish a small amount of rice extracted for the purpose of testing in a short time Since the rubber plate is used capability of bran removal is excellent and the grains are well finished The polished gr...

Страница 2: ...y opened Transparent bran receptacle The timing for discarding the removed bran can be seen at a glance Motor overload prevention If excessive force is applied to the motor and there is a risk of the...

Страница 3: ...the outlet of the removed bran The drive unit can catch fingers and severely injure them Status lamp On The device is ready to be used Off For safety the sensor is activated and the device is stopped...

Страница 4: ...ble the parts correctly Push the lever while the cover is closed If the sample is left in the polishing unit the clatter may be heard Push the lever until the sound is stopped The polished sample is e...

Страница 5: ...ishing in the preset time Cautions When using the Pearlest Timer TZ 910 it is required to set the power of the Compact Grain Polisher Pearlest TP 3000 always OFF If the power in ON the timer is disabl...

Страница 6: ...rlest is closed If the sample is left in the polishing unit the clatter may be heard Push the lever until the sound is stopped The polished sample will be ejected to the polished sample receptacle Whe...

Страница 7: ...barley barley polishing will become available Also the parts can be used for rice suitable for brewing sake In order to avoid loosening of the parts firmly fix with the supplied pallet Disc fixing sc...

Отзывы: