Kessler-Ellis Products 533K.2 Скачать руководство пользователя страница 1

http://www.kep.com

533K.2

Setpoint Generator / 

Time Based 

Process Adjuster 

990115 

05/08/07

KESSLER-ELLIS PRODUCTS 

10 Industrial Way East

Eatontown, NJ 07724

800-631-2165 • 732-935-1320

Fax: 732-935-9344

Installation and Operating Manual

Содержание 533K.2

Страница 1: ...om 533K 2 Setpoint Generator Time Based Process Adjuster 990115 05 08 07 KESSLER ELLIS PRODUCTS 10 Industrial Way East Eatontown NJ 07724 800 631 2165 732 935 1320 Fax 732 935 9344 Installation and Op...

Страница 2: ......

Страница 3: ...ck to Factory Setting 4 3 2 Programming and Operation of the Setpoint Generator With the 2 Keys 4 3 3 General Information about Programming 5 4 Programming 5 4 1 Call for the Programming Mode 5 4 2 Pr...

Страница 4: ...er programming this operation is defi ned by means of 2 freely selectable current or voltage values and by the increment During operation press the right key to increase the setpoint by the increment...

Страница 5: ...device accor ding to its intended purpose 3 It must be in perfect technical condition 4 Use this device in accordance with the instructions of the opera ting manual and the general safety notes 5 Tak...

Страница 6: ...vice the following message is displayed for 2 seconds Then the device type is displayed for 2 seconds followed by the software version also for 2 seconds After reading the EEPROM the device switches t...

Страница 7: ...displayed Press the right key to switch over bet ween YES and No 4 If YES is displayed and both keys are pressed the programming mode is called for no exits the program ming mode 3 3 General Informat...

Страница 8: ...peration If the value of parameter ou Hi was altered the output of the devi ce will automatically be set to the value of parameter ou Lo when it will be set back to operation SiGnal allows selecting t...

Страница 9: ...low limit the setpoint will be maintained at the value of ou Lo If he tries to exceed the upper limit the setpoint will be main tained at the value of ou Hi Note If during operation the operator switc...

Страница 10: ...imes PE X result from the setting of PEr The function cYcle allows defining the number of cycles to be carried out Selecting noCYcle will start an endless loop Press both keys simultaneously to switch...

Страница 11: ...ces only for the values appearing on the display display Low allows defining the minimum value to be displayed This value corresponds to the value ou Lo used for the output setpoint display High allow...

Страница 12: ...0 s ou 8 0 v PE 8 5 s 5 Technical Data Display 4 digit red 7 segment LED display height 8 mm Supply voltage 10 30 V DC electrically isolated Current consumption 39 mA at 25 C for a 20 mA output curren...

Страница 13: ...e 10 mVss Accuracy 0 1 of the final value 0 01 K Inputs 1 10 30 V DC 2 GND_1 3 GND_2 4 Hold Outputs 5 0 24 mA Iout 6 GND_3 7 0 12VDC Uout 6 Connecting diagram Block diagram and connection see point 1...

Страница 14: ...1 103 28 0 984 x 1 969 25 x 50 1 0 039 4 0 158 56 2 205 32 1 26 40 1 575 1 0 039 1 4 0 158 0 894 x 1 969 25 x 50 0 984 0 02 25 0 5 1 969 0 024 50 0 6 0 984 0 02 25 0 5 1 969 0 024 50 0 6 M3 1 26 0 004...