background image

OBN-14-BA-e-1510 

 

  20 

5.7  Using eye cups 

 
The  eye  cups  supplied  with  the  microscope  can  basically  be  used  at  all  times,  as 
they  screen  out  intrusive  light,  which  is  reflected  from  light  sources  from  the 
environment onto the eyepiece, and the result is better image quality. 
 
But  primarily,  if  eyepieces  with  a  high  eye  point  (particularly  suitable  for  those  who 
wear glasses) are used, then it may also be useful for user

s who don’t wear glasses, 

to fit the eye cups to the eyepieces. 
 
These  special  eyepieces  are  also  called  High  Eye  Point  eyepieces.  They  can  be 
identified  by  the  glasses  symbol  on  the  side.  They  are  also  marked  in  the  item 

description by an additional “H” (

example: HSWF 10x Ø 23 mm). 

 
When fitting the eye cups, make sure that the dioptre setting is not moved. We would 
therefore advise that you hold the dioptre compensation ring on an eyepiece with one 
hand while you fit the eye cup with the other. 
 
Before  using  the  microscope,  users  who  wear  glasses  must  remove  the  eye  cups, 
which you may find on High Eye Point eyepieces.  
 
As  the  eye  cups  are  made  of  rubber,  you  must  be  aware  that  when  you  are  using 
them,  they  can  become  slightly  dirty  through  grease  residues.  In  order  to  maintain 
hygiene, we would therefore recommend that you clean the eye cups regularly (e.g. 
with a damp cloth). 
 
 
 
                       

 

 

 
    

 

 

 

 

 
 
 
 
 
 
 

   Eye cups 
 
 
 

High Eye Point eyepiece  
(identified by the glasses symbol) 

 

 

Содержание OBN 141

Страница 1: ...hn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com User instructions Fluorescence microscope KERN OBN 14 OBN 141 OBN 147 OBN 148 Version 1 0 01 2015 Import r Impex Produkter...

Страница 2: ......

Страница 3: ...ndenser 13 5 Operation 13 5 1 Getting started 13 5 2 Pre focussing 14 5 3 Adjusting the interpupillary distance 15 5 4 Dioptre adjustment 15 5 5 Adjusting the magnification 16 5 6 Adjusting the Koehle...

Страница 4: ...n additional risk of triggering an electric shock 1 2 Notes on the electrical system Before connecting to a mains power supply you must make sure that you are using the correct input voltage The infor...

Страница 5: ...ich are too high or too low vibrations dust or a high level of humidity The ideal temperature range is between 0 and 40 C and a relative humidity of 85 should not be exceeded The device should always...

Страница 6: ...s these are highly flammable substances You must therefore keep it away from naked flames and electrical devices which can be switched on and off and only use it in well ventilated rooms However organ...

Страница 7: ...d into two main components Compound microscope KERN Professional Line Fluorescence reflected light unit The following user manual refers at first merely to the compound microscope The disquisition on...

Страница 8: ...erture adjustment Condenser Condenser Field lens with Field diaphragm Control dial X Y axis Specimen stage Fine adjustment knob Coarse adjustment knob Dimmer Tube connectors with dioptre adjustment ri...

Страница 9: ...OBN 14 BA e 1510 8 Rear view Adjusting ring torque Carrying handle Main switch Power connection Coarse adjustme nt knob Fine adjustment knob Fuse Condenser Focus dial...

Страница 10: ...B G OBN 147 Infinity Trinocular Halogen 100W Epi Fluorescence B G OBN 148 Infinity Trinocular Halogen 100W Epi Fluorescence B G UV V Eyepieces WF 10x 20 mm Objectives 4x 10x 20x 40x 100x Product dime...

Страница 11: ...OBN 14 BA e 1510 10...

Страница 12: ...11 OBN 14 BA e 1510 4 Assembly...

Страница 13: ...ongest magnification appears You must make sure that you do not touch the lenses with your bare fingers and that no dust enters the apertures For objectives which are marked OIL you must use an immers...

Страница 14: ...ccessories 5 Operation 5 1 Getting started The very first step is to establish a power connection using the mains plug You should first adjust the dimmer to a low level so that when you look through t...

Страница 15: ...soon as an image is recognisable no matter how sharp then you should only adjust the focus using the fine adjustment knob Adjusting the torque of the coarse and fine adjustment knob Next to the left a...

Страница 16: ...llary distance is set correctly 5 4 Dioptre adjustment The eye strengths of each eye of the microscope user can often be slightly different which in daily life has no consequences But when using a mic...

Страница 17: ...objectives you should use the silver ring above the objectives see illustration When rotating the nosepiece you must always make sure that the objective which is about to be positioned in the beam pat...

Страница 18: ...hragm When adjusting the Koehler lighting for the first time you must first select the lowest possible objective magnification so that you can carry out the following steps 1 Use the condenser focus w...

Страница 19: ...he condenser up so high that it collides with the object holder Therefore care is needed when doing this 4 Use the centring screws of the condenser holder to bring the image from the field diaphragm i...

Страница 20: ...3 of the pupil diameter If the eyepiece should be removed for checking then please make sure that no dirt or dust falls into the tube 7 It is possible to alter the brightness of the bulb using the di...

Страница 21: ...sses symbol on the side They are also marked in the item description by an additional H example HSWF 10x 23 mm When fitting the eye cups make sure that the dioptre setting is not moved We would theref...

Страница 22: ...Lower the specimen stage and position the 100x objective in the beam path 3 Bring the specimen stage or object slide to the objective very slowly until there is slight contact 4 Observe the object Th...

Страница 23: ...tained in the spectrum of the light source HBO or LED The excitation filter is only permeable for the according wave length After that the excitation light hits a dichroic mirror which reflects it tow...

Страница 24: ...23 OBN 14 BA e 1510 Overview of wave lengths for excitation and emission per excitation filter Blue line Wave length excitation Green line Wave length emission...

Страница 25: ...OBN 14 BA e 1510 24...

Страница 26: ...25 OBN 14 BA e 1510...

Страница 27: ...er for FL module Fixing Allen screw for microscope head Main body Connection point for microscope head Fixing screw for lamp housing 7 8 9 10 11 HBO LED lamp housing Power connection Screw for attachi...

Страница 28: ...device for field diaphragm Control lever for field diaphragm Centring device for aperture diaphragm Control lever for aperture diaphragm 6 7 8 9 10 Condenser control Screw for cover of lamp housing Ce...

Страница 29: ...fluorescence reflected light units available for the microscopes of the series OBN 14 They have the following specifications Article number Illumination Excitation filter Centring objective Input volt...

Страница 30: ...he reflected light unit for special fluorescence applications it will be favourable to adjust the microscope in the bright field mode This includes the placing of the sample adjusting the interpupilla...

Страница 31: ...reduction of the lamps life time Equally the lamp must not be switched on directly after a switch off process When pausing the observation you should always slide in the control lever for the illumin...

Страница 32: ...Use the two centring screws on the lamp housing for moving the light spot into the centre of the hair cross Warning Heat development on the lamp housing Changing the lamp HBO 1 Disconnect the FL refl...

Страница 33: ...he mains power supply socket With the device switched off and unplugged you can screw out the housing The defective fuse can be removed from its housing and be replaced with a new one After that you j...

Страница 34: ...lb can be pulled out of the socket and be replaced with a new one After the bulb holder has been replaced in the underside of the device and the screws replaced the bulb replacement procedure is compl...

Страница 35: ...ece see illustration on page 10 where you can simply insert the analyser see left illustration The polariser on the other hand is only placed on the ring holder of the field lens see right illustratio...

Страница 36: ...ng the microscope camera i e using the PC screen which is connected To do this the trinocular toggle rod on the righthand side of the microscope head must be pulled out The light from the microscope l...

Страница 37: ...This consists of a simple PH condenser a PH objective with a specific magnification 10x 20x 40x or 100x a PH slider which is adapted to the lens being used a centring telescope and two green filters...

Страница 38: ...es of the user using a green filter can produce a more effective and pleasant image To achieve this the green filter must be screwed onto the underside of the PH condenser 2 Comprehensive phase contra...

Страница 39: ...a black objective ring The black one is central and the white one possible is pushed to one side see left illustration g Now press the turnscrews fitted on the side of the condenser towards the centr...

Страница 40: ...ly centred The condenser is too low The field of view is dark or is not correctly illuminated The objective is not positioned correctly on the beam path The selector switch for the beam path is betwee...

Страница 41: ...Dirt dust on the front lens of the condenser Dirt dust on the object One side of the image is blurred The stage was not correctly fitted The objective is not positioned correctly on the beam path The...

Страница 42: ...y materials which you can dispose of at your local recycling centre Disposal of the storage box and device must be carried out by the operator in accordance with all national or regional laws in force...

Страница 43: ...______________________________________________________ __________________________________________________________ __________________________________________________________ ___________________________...

Отзывы: