3.3  Warranty 

The warranty expires in the following cases:  

 

  the instructions contained herein are not observed; 

  the scales are not used as intended; 

  the scales are modified or opened; 

  mechanical damage or damage caused by utilities or liquids; 

  natural wear and tear; 

  improper setting or incorrect electrical system; 

  the measuring mechanism is overloaded; 

  the scales fall. 

3.4  Monitoring of test resources 

As part of the quality assurance system, the technical measuring properties of the 
scales and (if applicable) the testing weight should be checked at regular intervals. 
To this end, the user responsible should determine an appropriate cycle, type and 
scope of such check. Information regarding the monitoring of test resources (scales 
and test weights) is available at KERN website (

www.kern-sohn.com

). The test 

weights and scales can be calibrated quickly and cheaply at KERN calibration labora-
tory accredited by DKD (Deutsche Kalibrierdienst) (in reference to the national 
standard). 
 

4  Basic safety instructions 

4.1  Observance of the instructions contained in the Operating Manual 

Carefully read this Operating Manual before setting and starting the appliance, even 
if you are already familiar with KERN balances. 
 

5  Transport and storage 

5.1  Verification upon acceptance 

Immediately check the received package for visible external damage —  the same 
applies to the device after unpacking. 

5.2  Packaging 

Keep all parts of the original packaging for any possible return transport.  
Only use the original packaging for return transport. 
Prior to dispatch, disconnect all cables and remove any loose/mobile parts.  
Install the transport protecting devices, if any. Protect all parts (such as the weighing 
platform, power unit, stand, operating panel, etc.) against slipping and damage. 
 

 

Содержание MBD 20K2

Страница 1: ...n GmbH Ziegelei 1 D 72336 Balingen E mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www kern sohn com Operating Manual Baby scales KERN MBD Version 1 0 2017 08 GB MBD B...

Страница 2: ...ptance 5 5 2 Packaging 5 6 Unpacking setup and start up 6 6 1 Site of installation location of use 6 6 2 Unpacking 6 6 2 1 Scales setup 6 6 2 2 Scope of delivery 6 6 3 Battery operation inserting and...

Страница 3: ...e 10 min Operating temperature 10 C 40 C Auto Off 20 s Power supply battery operation 2 x 1 5 V type AAA operation time 20 h Air humidity max 80 non condensing Dimensions completely assembled W x D x...

Страница 4: ...the baby placed on the weighing pan to avoid falling Proceed according to the guideline placed on the weighing pan 3 2 Improper use Do not expose the weighing pan to a prolonged load It may cause dam...

Страница 5: ...site www kern sohn com The test weights and scales can be calibrated quickly and cheaply at KERN calibration labora tory accredited by DKD Deutsche Kalibrierdienst in reference to the national standar...

Страница 6: ...bly warmer environment In this case acclimatize the device for approx 2 h at the ambient temperature Avoid static charge of the scales and persons to be weighed Avoid contact with water Major indicati...

Страница 7: ...Initial start up To obtain accurate weighting results using the electronic balances the devices must reach an appropriate operating temperature see Chapter 1 Warm up time The scales must be turned on...

Страница 8: ...hing can be tared by pressing the button during the subsequent weighing processes the scales will display the actual weight of the baby Place an object e g a towel or pad on the weighing pan Wait unti...

Страница 9: ...The scales are provided with an integrated memory function that allows to memorise the weight values and display them when necessary Memorising the weight values Start the scales by pressing ON OFF a...

Страница 10: ...calmly on the weighing pan Start the scales by pressing ON OFF and wait until the zero value appears Wait until the unstable symbol disappears Place the baby on the weighing pan Wait until the unstab...

Страница 11: ...ressive cleaning agents solvents etc but clean the device us ing only a cloth moistened with a mild soap lye or a household cleaning agent En sure that no liquid penetrates into the device Wipe the de...

Страница 12: ...ments of air Table floor vibration The weighing pan is in contact with solids or is in correctly installed Electromagnetic fields static charges choose an other location turn off the device causing th...

Отзывы: