CDE/CME/CDEE-BA-e-1014
27
9.3.2 Baud rate
The baud rate necessary for the measuring values transfer can be set.
In the following example the baud rate is set to 9600 baud.
Ö
With the weighing scale switched off, press
ON/OFF
and
TARE
-key
simultaneously until the first function “
Unit
“ appears.
Ö
Repeatedly press the
10x
-key until “
bAUd
“ appears.
Ö
Confirm by pressing the
-key. Current setting appears.
Ö
Now you can use the
10x
-key to select among the different settings
(see chpt. 8.3)
Ö
Changed setting will be imported by pressing the
key. The balance
returns automatically into weighing mode.
9.3.3 Selection printed edition
Use this function to select which data are sent via the RS232C interface.
To achieve this, follow the sequence of operations below:
Ö
With the weighing scale switched off, press
ON/OFF
and
TARE
-key
simultaneously until the first function “
Unit
“ appears.
Ö
Repeatedly press the
10x
-key until “
LAPr
“ appears.
Ö
Confirm by pressing the
key.
Ö
Now you can use the
10x
-key to select among the output parameters below:
Display
Status
Function
„Hdr“
On / Off
Edition of the headlines
„GrS“
On / Off
Edition of the total weight
„Net“
On / Off
Edition of the net weight
„tAr“
On / Off
Edition of the tare weight
„N7E“
On / Off
Edition of the stored weight
„PCS“
On / Off
Edition of quantity
„AUJ“
On / Off
Edition of the unit weight
„rqt“
On / Off
Edition of the reference quantity
„FFd“
On / Off
Edition of a page feeding
„FFE“
On / Off
Edition of a page feeding
at end printer output