7 Functions of display unit
7.1 Prior to weighing: ZERO-POINT CHECK
Prior to each weighing process ensure that the system is unloaded and clear of
obstructions. The display unit provides automatic zero adjustment. This means, that
small deviations from the zero-point are corrected automatically. If the display unit
does not correct the zero-point automatically you will have to carry out a manual
correction with the help of the
TARE
key.
7.2 Gross weighing
After the load was lifted, the display shows the gross value of the weighed weight.
7.3 Net weighing: TARING BY PRESSING A BUTTON
The display unit offers an option that allows tare weights to be reset to zero by
pressing a button. In this way net weight changes can be traced. After taring, the
display unit will once again start at the smallest display step.
¾
Lift the load.
¾
Press
TARE
button
The display unit shows zero.
The lit up display “NET“, indicates that a tare weight is active.
¾
Loading and unloading the net load.
The net value for the weighed weight is shown on the display.
For unloading this will be a negative value.
¾
The system reverts to standard weighing mode when a zero adjustment is carried
out in an unloaded state.
7.4 Net weighing: MANUAL TARE INPUT
You may enter the tare weight at any time, that is, regardless whether the scales are
in a loaded or unloaded state. To achieve higher accuracy, a tare weight with a
higher resolution may be entered, regardless of the size of the weight and the display
steps of the indicator.
¾
Press
PRE-
TARE
button
The most recently used tare value appears.
The segment on the right is flashing.
¾
Press the
TARE
key for three seconds if the indicated tare value is to be used again
or
VHB/VHS-BA-e-1012
11
Содержание 51596249
Страница 142: ...VHB VHS BA rus 1012 5 3 3 1 3 2 KERN 3 3...
Страница 143: ...VHB VHS BA rus 1012 6 3 4 KERN www kern sohn com DKD Deutsche Kalibrierdienst KERN 4 4 1 KERN 4 2 5 5 1 5 2...
Страница 144: ...6 6 1 2 0 1 0 1 10 40 C 0 3 VHB VHS BA rus 1012 7...
Страница 145: ...2 6 2 KERN VHB 4 x 1 5 V AA 6 3 4 x 1 5 V AA 3 LO BA 6 4 ON OFF UNIT 0 3 VHB VHS BA rus 1012 8...
Страница 146: ...6 5 KERN VHB NET HELP 1 HELP 2 HELP 3 HELP 4 PRE TARE HELP HELP 7 LO BA VHB VHS BA rus 1012 9...
Страница 147: ...6 6 TARE PRE TARE 1 TOTAL KERN VHB 1 KERN VHS 1 ON OFF UNIT ERRO2 2 VHB VHS BA rus 1012 10...
Страница 148: ...7 7 1 TARE 7 2 7 3 TARE NET 7 4 PRE TARE TARE VHB VHS BA rus 1012 11...
Страница 149: ...PRE TARE TOTAL PRE TARE TARE TARE NET 7 3 PRE TARE TARE TARE NET 7 3 PRE TARE TARE VHB VHS BA rus 1012 12...
Страница 150: ...7 5 TOTAL KERN VHS TOTAL TOTAL KERN VHS 00 0 0 VHB VHS BA rus 1012 13...
Страница 151: ...7 6 KERN VHS 1 2 3 1 2 c 3 C a 7 5 VHB VHS BA rus 1012 14...
Страница 153: ...VHB VHS BA rus 1012 16 8 8 1 8 2 KERN 8 3...
Страница 154: ...VHB VHS BA rus 1012 17 9 9 1 9 2 KERN 9 3...
Страница 155: ...VHB VHS BA rus 1012 18 10...