Wirnet iBTS
Document title : Installation and
Maintenance Manual
Version : 2.0
Author : SNI
Date : 04/12/2018
Classification
This document is the strict property of Kerlink and shall not be either copied nor sent without express
written authorization of Kerlink
Internal Use
Kerlink m2m technologies reserved rights
Confidential
Kerlink – 1 rue Jacqueline Auriol – 35235 THORIGNÉ-FOUILLARD
Page 75 / 221
Strict confidential
Note 2:
this indoor PoE injector must be connected to an industrial electrical installation
including lighting protections. It must include a main board with surge protections type 1
and a secondary board with surge protections type 2.
If the electrical installation does not meet those requirements, use an alternate PoE injector
featuring better surge protection as detailed in §1.6.1.6.
Note 3:
this PoE injector is intended for indoor applications only.
In case the PoE injector cannot be installed indoor, use an alternate PoE injector dedicated
to outdoor applications as detailed in §1.6.1.6.
1.6.1.3
Indoor AC/DC Midspan PoE injector 60W
The indoor AC/DC Midspan PoE injector 60W characteristics are detailed in the following
table:
Description
Specification
Ethernet data rates
10/100/1000Base-T
Number of ports
1
PoE compatibility
IEEE 802.3at
IEEE 802.3af compatible
PoE Output Power
60 Watts over 4 pairs
PoE Output Voltage
55 VDC
PoE Pin Assignment and Polarity
Data Pairs 1/2 (-) and 3/6 (+)
Spare Pairs 7/8 (-) and 4/5 (+)
Input Power Requirements
AC Input Voltage: 100 to 240 VAC
AC Input Current: 1.2A @100-240VAC
AC Frequency: 50 to 60 Hz
Dimensions
62 mm (W) x 38 mm (H) x 151 mm (L)
Weight
320g
Connectors
Shielded RJ-45, EIA 568A and 568B
Indicator
AC Power (Yellow)
Channel Power delivered over 4 pairs (Green)
Operating Ambient Temperature
-10°C to +40°C @ 60W
-10°C to +55°C @ 30W
Operating Humidity
Maximum 90%, Non-condensing
Storage Temperature
-20°C to +70°C
Storage Humidity
Maximum 95%, Non-condensing
Regulatory compliance
RoHS
WEEE
CE
Electromagnetic Emission & Immunity
FCC Part 15, Class B
EN 55022 Class B (Emissions)