background image

SB-593 Satellite Board

Unit 17 Park Farm Industrial Estate

01925-001 Rev. 1.2

Buntingford, Herts SG9 9AZ UK
TEL: 0870 444 7234  FAX: 0870 444 7240
Web: http://www.kerisystems.co.uk  E-mail: [email protected]

Page 1 of 16

SB-593

Quick S

tart Guide

This quick start guide is made up of a specification sheet, basic installation drawings and information, and short 
descriptions of key terms and concepts.

NOTE: The SB-593 may be used with either a PXL-250 or a PXL-500/PXL-510.

Figure 1: SB-593 Satellite Board

Содержание SB-593

Страница 1: ...tp www kerisystems co uk E mail sales kerisystems co uk Page 1 of 16 SB 593 Quick Start Guide This quick start guide is made up of a specification sheet basic installation drawings and information and...

Страница 2: ...e by 2 60 inches deep 24 65 cm by 20 85 cm by 6 60 cm Operating Temperature Humidity Range 0 F to 140 F 18 C to 60 C 0 to 90 Relative Humidity non condensing Controller with Satellite Board Power Requ...

Страница 3: ...lectric motor for a single door application install the door s reader to the TB 5 A reader connection on the controller for a two door application install the primary door s reader to the TB 5 A reade...

Страница 4: ...If you are installing the SB 593 which has two rows of connector pins on a PXL 250 controller which has one row of mounting holes it does not matter which row of connector pins are inserted in the mo...

Страница 5: ...rawing See page 7 for a sample Door Held Open Alarm A Door drawing See page 7 for a sample Door Held Open Alarm B Door drawing See page 8 for a sample General Purpose Output Normally Open Relay drawin...

Страница 6: ...ion if the power fails the door is unlocked see page 16 for information about fail safe lock applications Figure 5 Fail Safe Door Lock Output Relay 7 1 1 2 Fail Secure Door Lock Output Relay In a fail...

Страница 7: ...ed alarm out annunciation feature in the Doors software has configured these outputs for door held open annunciation The DHO alarm feature is not available in 16 bit Doors software applications If you...

Страница 8: ...n Relay Connection In the following application an event causes programming in the controller to close the normally open line temporarily turning on a video camera Figure 10 General Purpose Output Nor...

Страница 9: ...l Purpose Input drawings Table 3 Inputs TB 8 TB 9 Inputs Description TB 8 Pin 1 door status switch input normally closed TB 8 Pin 2 common ground TB 8 Pin 3 RTE input normally open TB 8 Pin 4 GPI 3 in...

Страница 10: ...tch opens and closes as the door is opened and closed Figure 12 Door Status Switch Input NOTE If a door switch is not installed a jumper must be installed across pins 1 and 2 of TB8 to prevent a conti...

Страница 11: ...o inform the controller that the user wishes to exit through the door associated with that controller The Auxiliary RTE input feature is not available in 16 bit Doors software applications Figure 14 A...

Страница 12: ...gure 1 on page 1 for output relay wiring locations See page 13 for a sample General Purpose Output Normally Closed Relay drawing See page 13 for a sample General Purpose Output Normally Open Relay dra...

Страница 13: ...osed Relay Connection In the following application an event causes programming in the controller to open the normally closed line temporarily turning off a sensor device Figure 17 General Purpose Outp...

Страница 14: ...sample General Purpose Input drawing Table 5 Inputs Table TB 8 TB 9 Inputs Description TB 8 Pin 1 GPI 1a a General Purpose inputs can accept either a normally closed or normally open signal The type...

Страница 15: ...kerisystems co uk Page 15 of 16 SB 593 Quick Start Guide 7 2 3 General Purpose Inputs For the application in Figure 19 a circuit is opened to create an input event at the controller Figure 19 General...

Страница 16: ...there pressing the button the switch remains open When someone desires to exit through a secure door they press the RTE button closing the circuit and generating a state change The controller then res...

Отзывы: