background image

MS-4000: ShootingStar Reader

1530 Old Oakland Road, Suite 100

01815-004 Rev. F

San Jose, CA  95112   USA
(800) 260-5265  (408) 451-2520  FAX (408) 441-0309
Web: http://www.kerisys.com  E-mail: [email protected]

Page 1 of 8

MS-4000

Quick Start Guide

The MS-4000 ShootingStar Reader

The MS-4000 ShootingStar Reader is intended for installation on a solid metal surface, in proximity 
applications where a vandal-proof reader is required. The reader is housed in a weatherproof, 
bulletproof stainless steel package.

1.0

Specifications

1.1

Dimensions

5.25 inches High x 2.00 inches Wide x 0.75 inches Deep

13.35 cm High x 5.08 cm Wide x 1.91 cm Deep

Figure 1:  MS-4000 Dimensions

Содержание MS-4000

Страница 1: ...uide The MS 4000 ShootingStar Reader The MS 4000 ShootingStar Reader is intended for installation on a solid metal surface in proximity applications where a vandal proof reader is required The reader...

Страница 2: ...nting screw 2 To mount the reader from the inside five holes need to be drilled One through hole 0 25 1 4 accommodates the reader cable Four 1 4 through holes correspond with four 1 4 x 20 tapped hole...

Страница 3: ...3 1 PXL 250 Connections The A reader connects to TB5 pins 1 3 and 4 no connection is made to pins 2 5 6 and 7 The B reader connects to TB6 pins 1 3 and 4 no connection is made to pins 2 5 6 and 7 Conn...

Страница 4: ...igure 3 Design 5 PXL 100 Connections NOTE Please contact customer support at Keri Systems for information regarding connecting a Reader to a Design 4 PXL 100 A Design 4 PXL 100 can be identified by th...

Страница 5: ...erisys com Page 5 of 8 MS 4000 Quick Start Guide 3 3 IntelliProx Connections The reader is connected to TB1 pins 1 5 and 6 no connection is made to pins 2 3 and 4 Connecting to the IntelliProx TB1 Fig...

Страница 6: ...nnunciate reader status the only way to verify reader operation is to present an enrolled card or tag to the reader and see that the door associated with the reader and controller unlocks This is vali...

Страница 7: ...either the reader or the device to provide a greater distance between the two 4 A jumper is not set correctly on the controller For a PXL 250 Verify there is a jumper across pins 1 and 2 of JP4 refer...

Страница 8: ...eader s cable has opened somewhere between the reader and the controller Verify the shield line from the controller to the reader is one continuous connected line Refer to the controller s installatio...

Отзывы: