![KEPCO KLR SERIES Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/kepco/klr-series/klr-series_developers-manual_1956489098.webp)
A-2
KLR-DEV 060713
A.4
*ESE? — STANDARD EVENT STATUS ENABLE QUERY
*ESE?
Syntax
:
*ESE?
Return value: Integer> value per Table A-2.
Description:
Returns the mask stored in the Standard Event Status Enable Register.
Contents of Standard
Event Status Enable register (*ESE) determine which bits of Standard Event Status register (*ESR)
are enabled, allowing them to be summarized in the Status Byte register (*STB). All of the enabled
events of the Standard Event Status Enable Register are logically ORed to cause ESB (bit 5) of the
Status Byte Register to be set (1 = set = enable function, 0 = reset = disable function). (See example,
Figure A-1.)
A.5
*ESR? — EVENT STATUS REGISTER QUERY
*ESR?
Syntax
:
*ESR?
Return value: <integer> (Value = contents of Event Status register as defined in Table A-2.)
Description:
Causes the power supply to return the contents of the Standard Event Status register. After it
has been read, the register is cleared.
The Standard Event Status register bit configuration is
defined in Table A-2 (1 = set, 0 = reset). The error bits listed in Table A-2 are also related to error
codes produced during parsing of messages and to errors in the power supply (see PAR. B.92 and
Table B-5)
•
Any 1xx type error sets the Command error bit (5).
•
Any 2xx type error sets the Execution error bit (4).
•
Any 3xx type error sets the Device error bit (3). The Device error bit will be set when Current Error
or Voltage Error is detected and the corresponding Status Questionable Enable bit is set.
•
Any 4xx type error sets the Query error bit (2).
Related Commands: *CLS, *ESE, *OPC. (See example, Figure A-1.)
A.6
*IDN? — IDENTIFICATION QUERY
*IDN?
Syntax
:
*IDN?
Return value: Character string
Description:
Identifies the instrument.
This query requests identification. The power supply returns a string
which contains the manufacturer name, model, option(s) installed, serial number and firmware ver-
sion.
The character string for standard models contains the following fields:
<Manufacturer>,<Model>-1200,<Last Calibration Date>,<Serial Number>,<Firmware revision>
The character string for two standard models in series contains the following fields:
<Manufacturer>,<Model _S> Series <Manufacturing Date master unit>,<Serial Number of master
unit>,<Firmware revision>
The character string for two standard models in parallel contains the following fields:
<Manufacturer>,<Model_P> Parallel <Manufacturing Date master unit>,<Serial Number of master
unit>,<Firmware revision>
The character string for standard models with R option (RODC) contains the following fields:
<Manufacturer>,<Model> RODC,<Last Calibration Date>,<Serial Number>,<Firmware revision>
The character string for E-Series models contains the following fields:
<Manufacturer>,<Model> LAN,<Last Calibration Date>,<Serial Number>,<Firmware revision>-<LAN
Firmware revision>
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......