5-10
KLR-DEV 060713
FIGURE 5-5. MAIN PANEL WINDOW
5.5.2
MAIN PANEL
The main panel window allows remote access to many power supply parameters without having
to operate the local controls and read the corresponding displays, and provides a demonstration
of the programming flexibility of the KLR power supply. The main panel is a real-time display of
output values and programmed parameters.
Various functions accessible via the panel (e.g voltage and current settings, protection limits,
trigger settings, etc.) may be altered either by clicking on the arrows to left of the applicable dis-
play or by using the mouse to highlight the setting, typing in a new value and then exiting the
field either by using the Tab key or by clicking the mouse button a second time. Refer to the
indicated paragraphs of the KLR User Manual for programming details.
The analog meters read actual output voltage and current; Two windows beneath the meters
are provided to enter voltage and current setpoints. The
Front Panel box
shows a digital read-
out of the voltage and current displayed on the analog meters (this is identical to the readouts
on the KLR front panel DC VOLTS and DC AMPERES displays) as well as showing messages
appearing on the front panel Status Display. The operating mode (CV or CC) Mode indicators
light to indicate whether the power supply is operating in either CV (constant voltage) or CC
(constant current) mode.
The
Output
button applies the programmed settings to the output terminals when set to ON or
keeps the output voltage at zero and current at minimum when set to OFF. When the output is
enabled the button color changes from gray to green.
Set Voltage
and
Set Current
windows are used to program the output voltage and current for
the unit. These settings may be changed by the user (see KLR User Manual, “Setting Voltage or
Current”).
The
Protection
button opens the Protection Window (Figure 5-6) which displays the present
overvoltage and overcurrent settings; these settings may be changed by the user. These
entries are automatically limited by the Limit Model settings as described in the KLR User Man-
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......