![KEPCO KLR SERIES Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/kepco/klr-series/klr-series_developers-manual_1956489117.webp)
KLR-DEV 060713
B-15
B.56 [SOURce:]VOLTage:[LEVel:]TRIGgered[:AMPLitude] COMMAND
VOLT:TRIG
Syntax:
Short Form: [SOUR:]VOLT:[LEV:]TRIG[:AMPL] <exp_value> MAX
Long Form: [SOURce:]VOLTage:[LEVel:]TRIGgered[:AMPLitude] <exp_value> MAX
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Programs voltage value to be transferred to output by *TRG commands.
Actual output voltage
will depend on load conditions. VOLT:TRIG MAX programs output voltage value to be transferred by
*TRG to be the lower of VOLT:LIM:HIGH or 80% of VOLT:PROT. If the value exceeds the maximum for
the model being programmed, error message -222,”Data out of range” is posted in output queue. If
value exceeds VOLT:LIM:HIGH value, a value corresponding to the voltage limit will be programmed.
This value is automatically checked after execution of VOLT:LIM:HIGH and VOLT:PROT, and is set to
zero volts if there is a conflict. NOTE: A current trigger must be entered at least once. (See example,
Figure B-1.)
B.57 [SOURce:]VOLTage:[:LEVel]TRIGgered[:AMPLitude]? QUERY
VOLT:TRIG?
Syntax:
Short Form: [SOUR]:VOLT[:LEV]:TRIG[:AMPL]? MAX
Long Form: [SOURce]:VOLTage[:LEVel]:TRIGgered[:AMPLitude]? MAX
Return Value: <exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns value representing voltage value to be programmed by *TRG command established by
VOLT:TRIG command).
VOLT:TRIG? MAX returns maximum permissible value that can be pro-
grammed by VOLT:TRIG (the lower of VOLT:LIM:HIGH and 80% of VOLT:PROT) (See example, Fig-
ure B-1.)
FIGURE B-5. PROGRAMMING AS VOLTAGE STABILIZER
NOTE: The following example assumes KLR 75-32 with limit model set for 36V, 32A and output operat-
ing in voltage stabilization mode. See Figure B-3 for directions on programming limit model set-
tings.
VOLT 21.8;CURR .5
Programs output voltage for 21.8V, output current for 0.5A.
OUTP ON
Enables output. NOTE: Load determines output operating mode; if
load resistance is greater than 21.8/0.5, output will operate as
voltage stabilizer.
MEAS:VOLT?
Returns measured output voltage, approximately 2.18E1 (21.8V)
assuming voltage stabilizer operation.
VOLT?
Returns 2.18E1 ( (21.8V, programmed output voltage).
VOLT 2.15
Programs output voltage to 2.15V.
VOLT?
Returns 2.15E0 (2.15V, programmed output voltage).
VOLT? MAX
Returns 3.6E1 (36V, the limit model voltage setting).
VOLT? MIN
Returns 0 (minimum allowable program voltage).
VOLT:PROT 6.5
For this model, minimum overvoltage protection is 0.2 x 75 = 15V,
therefore power supply returns error message -222 (Data out of
range, ESR bit 4 =1) and the limit remains unchanged.
VOLT:PROT 25
Sets overvoltage protection limit to 25V.
VOLT:PROT?
Returns 2.5E1 (25V).
VOLT 26
Returns error message -301 (Value bigger than limit, ESR bit 3=1)
and voltage setting remains unchanged at 2.15V.
VOLT:PROT?MAX
Returns 9E1. Maximum allowable overvoltage protection limit for
model is 90V, 20% above maximum voltage (75V for KLR 75-32).
Содержание KLR SERIES
Страница 2: ......
Страница 10: ......
Страница 42: ......
Страница 58: ...4 16 KLR DEV 060713 FIGURE 4 10 FUNCTION GENERATOR PANEL FIGURE 4 11 CONFIGURE User Sequence vi BLOCK DIAGRAM ...
Страница 59: ......
Страница 60: ......
Страница 61: ...FIGURE 4 13 FUNCTION GE ...
Страница 62: ......
Страница 86: ......
Страница 90: ......