B-6
KLR-DEV 060713
B.23 [SOURce:]LIST:DWELl? QUERY
LIST:DWEL?
Syntax:
Short Form: LIST:DWEL?
Long Form: LIST:DWELl?
Return Value: <value>
Description:
Identifies the dwell times entered for the list.
Starting at location established by LIST:QUERy,
returns comma-separated list of up to 16 values indicating the dwell time parameters entered. i.e., the
contents of LIST:DWEL locations of the List Data Table. Related Commands: LIST: DWEL,
LIST:QUERy.
B.24 [SOURce:]LIST:DWELl:POINts? QUERY
LIST:DWEL:POIN?
Syntax:
Short Form: LIST:DWEL:POIN?
Long Form: LIST:DWELl:POINts?
Return Value: <value> (0 to 250)
Description:
Identifies the number of locations for which time values have been entered and the next loca-
tion to be filled by a LIST:DWEL command.
If LIST:DWEL:POIN? returns 6, dwell times have been
entered for locations 0 through 5 and location 6 is the next to be filled by a LIST:DWEL command.
LIST:DWEL, LIST:DWEL:POIN.
B.25 [SOURce:]LIST:QUERy COMMAND
LIST:QUER
Syntax:
Short Form: LIST:QUER <int_value>
Long Form: LIST:QUERy <int_value>
int_value = 0 to 250
Description:
Determines first location to be queried by LIST:VOLT?, LIST:CURR?, LIST:DWEL?, LIST:CONT?
queries.
Related Commands: LIST:QUER?. (See example, Figure B-2.) Sending LIST:QUER 0 sup-
presses the 16-entry response to LIST:VOLT?, LIST:CURR?, LIST:DWEL? and LIST:CONT? and
causes the entire list to be returned. The list may be up to 2000 bytes (250 points x 10 characters).
B.26 [SOURce:]LIST:QUERy? QUERY
LIST:QUER?
Syntax:
Short Form: LIST:QUER?
Long Form: LIST:QUERy?
Return Value: <int_value>
Description:
Identifies first location to be queried by LIST:VOLT?, LIST:CURR?, LIST:DWEL?, LIST:CONT?
queries.
Related Commands: LIST:QUER. (See example, Figure B-2.)
B.27 [SOURce:]LIST:VOLTage COMMAND
LIST:VOLT
Syntax:
Short Form: LIST:VOLT[:LEV] <exp_value>, <exp_value>, . . . (to max of 250 data points)
Long Form: LIST:VOLTage[:LEVel] <exp_value>, <exp_value>, . . . (to max of 250 data points)
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E1 for 27.1
Description:
Adds the voltage value (in Volts) to list.
This command sequentially adds LIST:VOLTage values to
the main channel List Data Table locations. LIST:CLE sets starting location to 0. Next location indi-
cated by LIST:VOLT:POIN? The maximum number of entries is 250. Since the input buffer of the KLR
has a limit of 253 characters, multiple commands are necessary to complete the full 250 entries of the
list. If LIST:VOLT is entered for only the first location, that voltage level will apply to all steps when
either VOLT:MODE LIST or CURR:MODE LIST is executed. Related Commands: LIST:VOLT:POIN?,
LIST:CLE, *RST. (See example, Figure B-2.)
B.28 [SOURce:]LIST:VOLTage? QUERY
LIST:VOLT?
Syntax:
Short Form: LIST:VOLT?
Long Form: LIST:VOLTage?
Return Value: <value1>, <value2>, . . . to <value16>
Description:
Identifies the parameters (main channel) entered for the list.
Starting at location established by
LIST:QUER, returns comma-separated list of up to 16 values indicating the main channel parameters
entered. i.e., the contents of the main channel List Data Table. Related Commands: LIST: VOLT,
LIST:QUER. If LIST:CURR has any entries, an error message: -221,”Settings conflict” is posted in the
error queue. (See example, Figure B-2.)
Содержание KLR SERIES