BHK-MG (OPR) 032816
3-3
MENU
Command Entry
Press to enter Menu commands: press repeatedly to scroll through Menu func-
tions: (1) set LCD contrast, (2) GPIB address, (3) Baud Rate, (4) Loop Back
Test, (5) DCL control, (6) Power-Up Digital DC Output on/off, (7) speaker on/off,
(8) change calibration password, (9) restore previous calibration values,
(10) restore factory calibration values, (11) view firmware version number,
(12) set Power-up and RESET current, (13) set maximum voltage, (14) set max-
imum current, (15) current scale. Press ENTER, RESET or CLEAR to exit
Menu.
(1) 3.2.5,
(2) 3.3.3,
(3) 3.4.1
(4) 3.4.4
(5) 3.3.2
(6) 3.2.7.4
(7,)3.2.6,
(8) 4.5,
(9) 4.6,
(10) 4.7
(11) 3.2.15
(12) 3.2.8.1
(13, 14) 3.2.12,
(15) 3.2.10
OV SET
7
Command Entry
Press to set overvoltage protection value. Data entry required to enter the over-
voltage protection value; press ENTER to accept displayed value.
3.2.11
Data Entry
Press to enter number 7.
3.2.1.2
OC SET
8
Command Entry
Press to set overcurrent protection value. Data entry required to enter new over-
current protection value; press ENTER to accept displayed value.
3.2.11
Data Entry
Press to enter number 8.
3.2.1.2
CALIB
9
Command Entry
Press to enter Calibration status. Requires password entry; instructions appear
on LCD.
4.3
Data Entry
Press to enter number 9.
3.2.1.2
STORE
Command Entry
Press to store present values of output voltage and current and overvoltage and
overcurrent protection. Data entry required to select memory location where val-
ues are to be stored
3.2.13
EDIT
PROG
Command Entry
Press to select the starting memory location to be edited. Then use
or
to
view or modify the parameters of a specific memory location or to create a new
program.
3.2.16.1
STEP
4
Command Entry
Press to select starting address of program to be executed one step at a time.
Address is updated each time STEP is pressed.
3.2.16.3
Data Entry
Press to enter number 4.
3.2.1.2
TIME
5
Command Entry
Press to edit time value for specific memory location. Select memory location
(data entry), then enter time value, 0.01 to 655.35 seconds (data entry).
3.2.16.1.1
Data Entry
Press to enter number 5.
3.2.1.2
RUN
6
Command Entry
Press to run a program. Requires data entry to select starting location. Press
ENTER to accept displayed value.
3.2.16.2
Data Entry
Press to enter number 6.
3.2.1.2
RECALL
Command Entry
Press to recall previously stored values of output voltage and current, and over-
voltage and overcurrent protection. The previously stored output state (enabled
or disabled) will also be recalled. Data entry required to select memory location
containing values to be recalled; press ENTER to accept displayed value.
3.2.14
CLEAR
Data Entry
Press to exit Data Entry status; any numbers entered are lost. Restores Com-
mand Entry status
3.2.9
1
Data Entry
Press to enter number 1.
3.2.1.2
TABLE 3-2. KEY FUNCTIONS (CONTINUED)
KEY
POWER SUPPLY
STATUS ACTIVE
DESCRIPTION
REFERENCE
PARAGRAPH
Содержание BHK 1000-0.2MG
Страница 2: ......
Страница 6: ......
Страница 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Страница 18: ...xii BHK MG032816 ...
Страница 24: ...1 6 BHK MG OPR 032816 FIGURE 1 2 BHK SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 ...
Страница 25: ...BHK MG OPR 032816 1 7 FIGURE 1 2 BHK SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2 ...
Страница 46: ......
Страница 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Страница 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Страница 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Страница 116: ......
Страница 154: ......