BHK-MG (OPR) 032816
B-13
B.53
[SOURce:]VOLTage:LIMit[:HIGH]?
QUERY
VOLT:LIM[:HIGH]?
Syntax:
Short Form: [SOUR:]VOLT:LIM[:HIGH]? Long Form: [SOURce:]VOLTage:LIMit[:HIGH]?
Return Value: <exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns value representing voltage limit set by VOLT:LIM[:HIGH] command.
Related Com-
mands: VOLT:LIM[:HIGH], VOLT. (See example, Figure B-5.)
B.54
[SOURce:]VOLTage:MODE COMMAND
VOLT:MODE
Syntax:
Short Form: [SOUR:]VOLT:MODE (FIX | LIST)
Long Form: [SOURce:]VOLTage:MODE (FIXed | LIST)
Description:
Allows the user to execute or stop a list.
The default mode is FIX: the power supply executes com-
mands normally, and LIST commands can be issued to establish the parameters and sequence of a
list.
When VOLT:MODE LIST is issued, a list is executed (See LIST commands and Figure B-3). While
the list is being executed, LIST commands are not accepted and will produce a command error.
Issuing VOLT:MODE FIX while the list is running will stop the execution of the list and return power
supply to settings in effect prior to running the list. If the list runs to completion, the settings of the last
step of the list will be in effect.
Related Commands: LIST commands. (See example, Figure B-3.)
B.55
[SOURce:]VOLTage:MODE? QUERY
VOLT:MODE?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:MODE?
Long Form: [SOURce:]VOLTage[:LEVel]:MODE?
Return value:
FIXED or LIST
Description:
Identifies active voltage mode.
Returns LIST while list is being executed. Returns FIXED while in
fixed (default) mode of operation. Related Commands: LIST commands. (See example, Figure B-3.)
B.56
[SOURce:]VOLTage:PROTection[:LEVel] COMMAND
VOLT:PROT
Syntax:
Short Form: [SOUR:]VOLT:PROT[:LEV] <exp_value>
Long Form: [SOURce:]VOLTage:PROTection[:LEVel] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Sets overvoltage protection level for power supply.
If the value is out of the acceptable overvolt-
age range for the power supply model, error message -222,”Data out of range” is posted in the output
queue. If the power supply output exceeds the voltage protection level programmed, the power supply
circuit breaker trips. (See example, Figure B-5.)
B.57
[SOURce:]VOLTage:PROTection[:LEVel]?
QUERY
VOLT:PROT?
Syntax:
Short Form: [SOUR:]VOLT:PROT[:LEV] MIN, MAX
Long Form: [SOURce:]VOLTage:PROTection[:LEVel] MIN, MAX
Return Value: <exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Returns value representing voltage protection level.
VOLT:PROT? returns value set by
VOLT:PROT. VOLT:PROT? MAX returns maximum voltage protection value (see Table 1-2). This
value is determined at the factory and cannot be changed by the user. VOLT:PROT?MIN returns the
minimum voltage protection value (always 0). (See example, Figure B-4.)
B.58
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPlitude] COMMAND
VOLT:TRIG
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:TRIG[:AMP] <exp_value>
Long Form: [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPlitude] <exp_value>
<exp_value> = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1
Description:
Programs voltage value to be transferred to output by *TRG commands.
Actual output voltage
will depend on load conditions. If the value exceeds the VOLT:LIM[:HIGH] value, error message -
222,”Data out of range” is posted in output queue. (See example, Figure B-1.)
Содержание BHK 1000-0.2MG
Страница 2: ......
Страница 6: ......
Страница 17: ...BHK MG032816 xi FIGURE 1 1 BHK MG SERIES PROGRAMMABLE POWER SUPPLY ...
Страница 18: ...xii BHK MG032816 ...
Страница 24: ...1 6 BHK MG OPR 032816 FIGURE 1 2 BHK SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2 ...
Страница 25: ...BHK MG OPR 032816 1 7 FIGURE 1 2 BHK SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2 ...
Страница 46: ......
Страница 101: ...BHK MG OPR 032816 3 55 FIGURE 3 20 SERIES AUTOMATIC CONFIGURATION ...
Страница 109: ...BHK MG OPR 032816 3 63 FIGURE 3 23 PARALLEL AUTOMATIC CONFIGURATION ...
Страница 114: ...3 68 BHK MG OPR 032816 FIGURE 3 25 PARALLEL MASTER SLAVE CURRENT MODE CONFIGURATION ...
Страница 116: ......
Страница 154: ......