16 USEFUL FUNCTIONS
16-24
CONFIGURING THE SQL CONTROL SIGNAL
If you connect an external device, such as a TNC or PC, to
the ACC 2 connector on the rear panel, you can configure
the SQL control signal condition with the MSQ pin and
SSQ pin of the ACC 2 connector.
Refer to "INSTALLING AND CONNECTING THE
TRANSCEIVER" for the details of connector.
SELECTING THE MSQ/SSQ LOGIC
You can configure the logic of the SQL control signal of
the MSQ pin and SSQ pin.
1 Press [ADV.] (F) from the Menu screen to open the
Advanced Menu screen.
2 Access Menu 18, "MSQ Logic State" (Main band), or
Menu 19, "SSQ Logic State" (Sub Band).
3 Press [SELECT] (F4) to allow editing of the parameter
box.
4 Press [-] (F4) or [+] (F5) to select "Low" or "Open".
The default is "Low" for both the main band and the sub
band.
5 Press [
] (F1).
6
Press [MENU] to exit.
Note:
◆
The VoIP application installed in a PC detects the busy state even
after the transceiver power ( ) has turned OFF, select "Open" for
Menu 18, "MSQ Logic State" (Main Land), or Menu 19, "SSQ Logic
State" (Sub Band). As well, you must configure the logic of the
busy state detection in the VoIP application to be the same as the
transceiver configurations.
CONFIGURING THE MSQ/SSQ OUTPUT CONDITIONS
You can configure the method to change the conditions of
the SQL control signal transferred from the MSQ pin and
SSQ pin.
1 Press [ADV.] (F) from the Menu screen to open the
Advanced Menu screen.
2 Access Menu 20, "MSQ Reverse Condition" (Main
band), or Menu 21, "SSQ Reverse Condition" (Sub
Band).
3 Press [SELECT] (F4) to allow editing of the parameter
box.
4 Press [-] (F4) or [+] (F5), or rotate the MULTI/CH
control to select the signal output conditions.
Available parameters are "Busy", "Sql", "Send", "Busy-Send",
"Sql-Send", and "Off". The default is "Sql" for both the main
band and the sub band.
5 Press [
] (F1).
6
Press [MENU] to exit.
The SQL control signal is transferred from the MSQ
pin and SSQ pin for the main band and sub band
independently.
Configured Value
Operation
Off
Fixed at low (inactive).
Busy
The SQL control signal becomes high (active)
regardless of the matching status of the received
CTCSS frequency.
Sql
If the CTCSS signaling is active, the SQL control
signal becomes high (active) when the received
CTCSS frequency coincides with the CTCSS
frequency configured for the transceiver.
If the CTCSS signaling is inactive, the SQL control
signal becomes high (active) when the CTCSS
frequency is received, regardless of the matching
status of the received CTCSS frequency.
Send
The SQL control signal becomes high while the
transceiver is transmitting.
Busy-Send
The SQL control signal becomes high while the
transceiver is transmitting and receiving.
Sql-Send
If "Sql" and "Send" are configured, the SQL control
signal becomes high.
Содержание TS-990S
Страница 1: ... B62 2389 10 09 08 07 06 05 04 03 02 01 HF 50 MHz TRANSCEIVER TS 990S INSTRUCTION MANUAL 1 01 ...
Страница 2: ......
Страница 42: ......
Страница 54: ......
Страница 78: ......
Страница 154: ......
Страница 164: ......
Страница 168: ......
Страница 192: ......
Страница 224: ......
Страница 232: ......
Страница 270: ......
Страница 284: ......
Страница 290: ......