TKR-850
48
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
19
LD2
O
Latch data output for DA converter
20
FWD
I
RF power down signal input
21
STB
O
Strobe output for shift register
22
CK
O
Clock output
23
DT
O
Data output
24
LDT
I
Lock detector for TX PLL
25
LDR
I
Lock detector for RX PLL
26
EPT
O
Enable output for TX PLL
27
EPR
O
Enable output for RX PLL
28
CP
O
Clock output for PLL
29
DP
O
Data output for PLL
30
SC
I
Squelch control signal input
31
RSSI
I
RSSI signal input
32
ASQ
I
Squelch signal input
33
GND
–
Ground
34
NC
–
No connection
35
DET
I
Detection signal input
36
NC
–
No connection
CN603
1
SB
O
Power supply output after power switch
To ACC
2
SB
O
Power supply output after power switch
15 pin
3
GND
–
Ground
connector
4
GND
–
Ground
CN604
1
AO5
O
Auxiliary output 5 (FPU selectable)
2
AO4
O
Auxiliary output 4 (FPU selectable)
To ACC
3
AO3
O
Auxiliary output 3 (FPU selectable)
15 pin
4
SPO
O
External speaker output
connector
5
SPO
O
External speaker output
6
AO2
O
Auxiliary output 2 (FPU selectable)
7
AO1
O
Auxiliary output 1 (FPU selectable)
8
SPI
I
Internal speaker input
9
RSSI
O
RSSI signal output
10
RD
O
RX data output
11
SPG
–
External speaker ground
12
SPG
–
External speaker ground
CN605
1
SPO
O
Internal speaker AF output
2
SPG
–
Internal speaker ground
CN606
1
NC
–
No connection
2
NC
–
No connection
To ACC
3
SPM
I
Speaker mute signal input
25 pin
4
IO6
I/O Programable I/O 6
D-sub
5
RXG
–
RX signal ground
connector
6
IO5
I/O Programable I/O 5
7
RA
O
RX audio output (voice)
8
IO4
I/O Programable I/O 4
9
RD
O
RX data output (voice & data)
10
IO3
I/O Programable I/O 3
11
TA
I
TX audio input (voice)
12
IO2
I/O Programable I/O 2
13
TD
I
TX data input (data or signaling)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
14
IO1
I/O Programable I/O 1
15
DG
–
Control line ground
16
TXG
–
TX signal ground
17
AI3
I
Auxiliary input 3 (FPU selectable)
18
NC
–
No connection
19
AI2
I
Auxiliary input 2 (FPU selectable)
20
SC
O
Squelch control output
21
AI1
I
Auxiliary input 1 (FPU selectable)
22
EPTT
I
External press-to-talk switch input
23
TXD2
O
RS-232C output signal (for FPU)
24
EMON
I
External monitor switch input
25
RXD2
I
RS-232C input signal (for FPU)
26
NC
–
No connection
27
NC
–
No connection
28
NC
–
No connection
29
NC
–
No connection
30
NC
–
No connection
RX VCO Unit (X58-480X-XX)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN300
1
FIN
I
Prescaler RF signal input
2
5C
I
Common 5V input
3
LDR
O
Lock detector for RX PLL
4
EPR
I
Enable input for RX PLL
5
DP
I
Data input for PLL
6
CP
I
Clock input for PLL
7
REF
I
Reference frequency signal input
CN350
1
GND
–
Ground
2
SRR
I
Switching signal input for RX VCO
3
8CL
I
8V input through the ripple filter
4
CV
I
RX PLL lock voltage
5
9CL
I
9V input through the ripple filter
6
NC
–
No connection
CN351
1
VO
O
RX VCO output
2
GND
–
Ground
TX VCO Unit (X58-481X-XX)
Connector Terminal Terminal I/O
Terminal function
No.
No.
Name
CN300
1
FIN
I
Prescaler RF signal input
2
5C
I
Common 5V input
3
LDT
O
Lock detector for TX PLL
4
EPT
I
Enable input for TX PLL
5
DP
I
Data input for PLL
6
CP
I
Clock input for PLL
7
REF
I
Reference frequency signal input
CN350
1
GND
–
Ground
2
STT
I
Switching signal input for TX VCO
TERMINAL FUNCTION