RXD-M32MD
8
CIRCUIT DESCRIPTION
3. AUTO FAB adjusting mode
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
Step 2
Press the
SKIP DOWN( )
button three times AUTO FAB adjustment menu
[_AUT_FAB_ _]
Step 3
Press the MD PLAY button 1 time
End of automatic adj. step 4
High reflection disc step 5
Step 4
Press the MD STOP button
AUTO FAB adjustment menu, step 2
Step 5
Message output for 1 sec. AUTO FAB.
Adjustment menu(high reflection disc)
• : measurement value : FAB value in measurement, : C1 error value in measurement, : FAB
value
• If the STOP button is pressed twice while the AUTO FAB adjustment is displayed, the state is change to the TEST mode
STOP state.
Step 1
Test mode STOP state
[ t s m
e
]
Step 2
Press the SKIP DOWN(
4
) button 4 times. RESULT sub-menu
[ _ R S T _ Y O B I _ ]
Step 3
Press once the MD PLAY button. Indication of measurement value
[ R F G : _
_ _
_ _
]
Step 4
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ R C G : _
_ _
_ _
]
Step 5
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ P T G : _ _ _ _ _
]
Step 6
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ G T G : _ _ _ _ _
]
Step 7
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ P C H : _ _ _ _
]
Step 8
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ G C H : _ _ _ _
]
Step 9
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ S A G : _ _ _
]
Step 10
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ S B G : _ _ _
]
Step 11
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ S E G : _ _ _
]
Step 12
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ S F G : _ _ _
]
Step 13
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ H A O :
_ _ _]
Step 14
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ H B O :
_ _ _]
Step 15
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ H E O :
_ _ _]
Step 16
Press once the SKIP DOWN(
4
) button. Indication of measurement value
[ H F O :
_ _ _]
4
) button. Indication of measurement value
[ L A O :
_ _ _]
4
) button. Indication of measurement value
[ L B O :
_ _ _]
4
) button. Indication of measurement value
[ L E O :
_ _ _]
4
) button. Indication of measurement value
[ L F O :
_ _ _]
4
) button. Indication of measurement value
[ T C O : _
_ _ _]
4
) button. Indication of adjustment error sequence No.
[ Y O B : _
_ _ _]
4
) button. Indication of adjustment status
[ D I F : _
_ _ _]
4
) button. Indication of pre-adjustment not completed (00)/completed (4B)
[ A D J : _
_ _ _]
Press once the MD STOP button. RESULT sub-menu state
[ _ R S T _ Y O B I _ ]
4. RESULT sub-mode
Step No.
Setting Method
Remarks
Display
: Other various informations
When the (
¡
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the (
1
)button in remote controller is pressed while the setting is displayed, the setting increases,
and a new setting is stored in RAM.
When the (
¡
) or (
1
)button in remote controller is pressed continously, steps is change by 100ms period.
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299