Scan List
In order to use List Scan, target members for List Scan must be registered in a Scan List. A maximum of 128 Scan Lists
can be configured. In each Scan List, a maximum of 31 Zone-channels can be registered as target members for List Scan.
Scan Type (Scan List)
In order to register a target member for List Scan,
Scan Type (Scan List)
must be configured.
Table 6-1 Scan Type (Scan List)
Configuration
Description
Conventional
A Zone-channel in a system where “Analog Conventional”, “P25 Conventional”, “NXDN
Conventional”, or “DMR Conventional” is configured in
System Type
can be registered as a
member for List Scan. Configuring a Priority Channel enables Priority Scan.
P25 Trunking
A Zone-channel in a system where “P25 Trunking” is configured in
System Type
selected in
System Number
can be registered as a member for List Scan. Configuring a Priority Channel
enables Priority Monitor Scan.
Limited Talkgroup
A Zone-channel in a system where “P25 Trunking” is configured in
System Type
selected in
System Number
, or a Zone-channel in a system where “Analog Conventional” or “P25
Conventional” is configured in
System Type
can be registered as a member for List Scan. No
Priority Channel can be configured. (Refer to
.)
LTR and Conventional
A Zone-channel in a system where “LTR Trunking”, “Analog Conventional”, “P25 Conventional”,
“NXDN Conventional”, or “DMR Conventional” is configured in
System Type
can be registered
as a member for List Scan.
Scan List Number (Channel)
List Scan is executed according to the Scan List Number configured for the channel where scan is initiated. According to
the configuration in
Scan List Number
, List Scan is executed as follows:
Table 6-2 Scan List Number (Channel)
Configuration
Description
Zone Common
List Scan is executed by referring to the
Scan List Number
configured for the zone.
1 to 128
List Scan is executed according to the List Number in the corresponding Scan List.
None
List Scan is not executed.
Configuration using KPG-D1/ D1N
Configuring
Scan List
(
Transceiver Settings > Scan Information > Scan List > Members)
Changing the Scan List (Scan Program)
A desired Zone-channel can be registered as a member for List Scan in the Scan List by operating the transceiver. Also, a
registered member in the Scan List can be deleted from the list.
The Scan List can be edited in Scan Program Mode.
Pressing the
Scan Program
key places the transceiver in Scan Program Mode.
Or, pressing the
Menu
key to enter Menu Mode and then selecting “Scan Program ” places the transceiver in Scan Program
6 SCAN
6.3 Scan by Registering Multiple Target Channels for Scan in the List (List Scan)
P25 FUNC (K)/Ver 2.20