![Kenwood NX-5000 series Скачать руководство пользователя страница 163](http://html.mh-extra.com/html/kenwood/nx-5000-series/nx-5000-series_manual_1956164163.webp)
3.2
Configuration Related to Transmission and Reception in
Emergency Mode
The transceiver can have a maximum of 8 configurations related to transmission and reception in Emergency Mode as
Emergency Profile
. By allocating
Emergency Profile
to each zone or channel, the Emergency behavior of the transceiver
can vary depending on the zone or channel.
The functions that can be configured as an Emergency Profile are as follows:
0
Emergency Channel Type
0
Emergency Zone-Channel
0
Emergency Mode Type
0
Emergency Cycle
0
Duration of Locator Tone 1
0
Transmit Duration
0
Duration of Locator Tone 2
0
Receive Duration
0
Emergency LED
The common functions in Emergency Mode are as follows. One configuration from below is available for the transceiver:
0
Emergency Display
0
Emergency Microphone Sense
0
Emergency Text
0
Text
0
Background Transmission
0
Emergency Channel Lock
0
Suspended Power-off
0
Surveillance Mode
0
Functions related to Lone Worker
0
Functions related to Activity Detection
Emergency Profile
can be configured for each zone or channel. If “Common” is configured in
Emergency Profile
for a
channel, the transceiver executes the Emergency behavior by using
Emergency Profile Number
configured for the zone
of the channel.
Also,
Emergency Alarm
can be configured for each system in a P25 Conventional system.
In a P25 Trunking system,
Emergency Talkgroup
and
Emergency Alarm
can be configured for each system.
Configuration using KPG-D1/ D1N
0
Configuring various functions of
Emergency Profile
(
Transceiver Settings > Emergency Information >
Emergency Profile)
0
Configuring Common Functions for
Emergency Mode
(
Transceiver Settings > Emergency Information >
General)
3 COMMUNICATIONS IN AN EMERGENCY
3.2 Configuration Related to Transmission and Reception in Emergency Mode
P25 FUNC (K)/Ver 2.20
143