![Kenwood NX-5000 series Скачать руководство пользователя страница 105](http://html.mh-extra.com/html/kenwood/nx-5000-series/nx-5000-series_manual_1956164105.webp)
Invalid ID State
If registration to a system is rejected such as because of the improper use of the transceiver, the transceiver records this
system, and registration to the system does not subsequently occur. This state is called Invalid ID State.
If the transceiver enters the Invalid ID State, “Sys Refused” appears on the display.
Menu
Zone+
Z o n e 1
T a l k g r o u p 1
S y s R e f u s e d
12 : 34
A
M
Note
0
Record of a system rejected for registration is cleared if the transceiver is turned OFF.
0
While in the Invalid ID State, the transceiver is in a state allowing receipt of signals from a control channel in the area,
but various communications cannot be initiated because the transceiver is not registered to a system.
0
While in the Invalid ID State, the transceiver cannot enter Emergency Mode.
0
If any of the following keys are pressed or any of the following functions are selected in
Menu
mode while the transceiver
is in the Invalid ID State, a Key-entry Error Tone (1 beep) sounds from the transceiver and the function does not function.
Auto Dial
Individual Call
Regroup Request
Site Lock
System Search
Status
Message
Send the GPS Data
Rekey Request
0
If the configuration of
Coverage Type
for a system is “Inter-System” or “Inter-WACN”, the transceiver can roam between
systems. In this case, the transceiver does not enter the Invalid ID State because the behavior of the transceiver is to
search for other systems.
2 P25 TRUNKING SYSTEM
2.4 Control Channel Hunt
P25 FUNC (K)/Ver 2.20
85