Man-1112 Sigma XT+_23
Page 10 of 52
Table 2 - Compatible detectors
Model
Type
Manufacturer
Maximum Number per zone
SLR-E/SLR-E3 OPTICAL
Hochiki
32
SIJ-E/ IONISATION
Hochiki
32
DCD-1E/DCD-AE3 HEAT
Hochiki
32
DCD-2E HEAT
Hochiki
32
DCD-1RE/DCD-CE3 HEAT
Hochiki
32
DFG-60E HEAT
Hochiki
32
DFJ-60E/DFJAE3 HEAT
Hochiki
32
DFJ90-E/DFJCE3 HEAT
Hochiki
32
SPB-ET BEAM
Hochiki
8
SRA-ET BEAM
Hochiki
5
55000-200/210 - SERIES 60
IONISATION
Apollo
32
55000-300 - SERIES 60
OPTICAL
Apollo
32
55000-100 - SERIES 60
HEAT
Apollo
32
55000-101 - SERIES 60
HEAT
Apollo
32
55000-102 - SERIES 60
HEAT
Apollo
32
55000-103 - SERIES 60
HEAT
Apollo
32
55000-104 - SERIES 60
HEAT
Apollo
32
55000-215 -SERIES 65
IONISATION Apollo
32
55000-216 - SERIES 65
IONISATION Apollo
32
55000-217 - SERIES 65
IONISATION Apollo
32
55000-218 - SERIES 65
IONISATION Apollo
32
55000-219 - SERIES 65
IONISATION Apollo
32
55000-220 - SERIES 65
IONISATION Apollo
32
55000-315 - SERIES 65
OPTICAL Apollo 32
55000-316 - SERIES 65
OPTICAL
Apollo
32
55000-317 - SERIES 65
OPTICAL
Apollo
32
55000-120 - SERIES 65
HEAT Apollo
32
55000-121 - SERIES 65
HEAT
Apollo
32
55000-122 - SERIES 65
HEAT
Apollo
32
53541-151 - SERIES 30
IONISATION
Apollo
32
53541-152 - SERIES 30
IONISATION
Apollo
32
53551-101 - SERIES 30
OPTICAL
Apollo
32
53531-221 - SERIES 30
HEAT
Apollo
28
53531-211 - SERIES 30
HEAT
Apollo
28
53531-212 - SERIES 30
HEAT
Apollo
28
53531-213 - SERIES 30
HEAT
Apollo
28
53531-214 - SERIES 30
HEAT
Apollo
28
ORB-OP-12001-APO Optical
Apollo
15
ORB-OH-13001-APO Multisensor
Apollo
15
ORB-HT-11001-APO A1R
Heat
Apollo
15
ORB-HT-11002-APO A2S
Heat
Apollo
15
ORB-HT-11003-APO BR
Heat
Apollo
15
ORB-HT-11004-APO BS
Heat
Apollo
15
ORB-HT-11005-APO CR
Heat
Apollo
15
ORB-HT-11006-APO CS
Heat
Apollo
15
NID-58 IONISATION
Nittan
32
2KC/2KD OPTICAL
Nittan
32
2SA-LS/2SA-70T-LS HEAT
Nittan
32
TCA-70-LS HEAT
Nittan
32
NFD-18-2/NFD-18-5 FLAME
Nittan
3
NID-48F IONISATION
Nittan
32
NS-12-7 HEAT
Nittan
32
NC-9C-70T HEAT
Nittan
32
ECO1002 HEAT/PHOTO
System
Sensor
21
ECO1003 PHOTO
System
Sensor
26
ECO1005 HEAT
System
Sensor
22
ECO1005T HEAT
System
Sensor
22
Although the current consumption of many detection devices would allow more than 32 to be connected to a zone,
this number should be limited to 32 to ensure that a short or open circuit on the wiring does not prevent the
indication of a fire alarm from more than 32 fire detectors and/or call points as required by European standard
EN54-2. If an active end of line LCMU (K14060) is used fit a maximum of 20 detectors per zone.
Содержание Sigma XT Plus
Страница 1: ...Sigma XT Extinguishant Control Panel Operation and Maintenance Manual Man 1112 Issue 23 March 2016...
Страница 15: ...Man 1112 Sigma XT _23 Page 15 of 52 Detection panel terminals...
Страница 16: ...Man 1112 Sigma XT _23 Page 16 of 52 Extinguishing module terminals...
Страница 51: ...Man 1112 Sigma XT _23 Page 51 of 52...
Страница 52: ...Man 1112 Sigma XT _23 Page 52 of 52 Man 1112...