background image

19 

NOTE:

 The Obstruction Sensitivity /Stall Force is adjustable in 9 levels. 

 

13. 

If  all  of  data  is  set  and  no  other  change needed,  press  “FUNC”  Button.  “-  -”  appears  on  the Digital 

Display, and the opener enters standby mode. 

 

 

Indicate Illustration on the Digital Display When Gate Opener is 

Running

 

The RIGHT image on Digital Display symbolizes motor of ARM 1 when the gate opener is running. The 

LEFT image on Digital Display symbolizes motor of ARM 2. 

When  the  motor  is  run  to  gate  -open  direction  or  gate  -close  direction,  the  image  on  Digital  Display 
indicates “n” or “u” respectively. 
When the motor is not running, the Digital Display indicates “- -”. 
When G

ate Opener 2 is set as Master gate (i.e. when “10” indicated at P2 set mode in the Control Board), 

the Digital Display flashes “-n” before the gate completely opens and closes. 
 

 

How to Operate 

The user may operate the opener once all adjustment setting is finished. 

With  the  gate  in  its  closed  position,  press  and  release  the  remote  control,  the  gate  will  move  to  the 

programmed opening position and stop. 

With  the  gate  in  its  opened  position,  press  and  release  the  remote  control,  the  gate  will  move  to  the 

programmed closing position and stop. 

While the gate is moving, press and release the remote control, the gate will stop moving immediately. The 

next  command  from  the  remote  will  reverse  the  gate  direction  and  the  gate  will  stop  at  its  programmed 

opening/closing position. 

The gate will stop in case of obstruction during opening. The command from the remote control will reverse 

the gate direction and the gate will stop at its programmed closing position. 

The gate will reverse in case of obstruction or stall force during closing, and it will move to the programmed 

opening position. 

 

 

 

 

Installation for Push-to-Open Gates 

  Ensure the gate does not open into public areas. 

The connection by 

“Push to Open”

 is different from the connection by 

“Pull to Open”

.   

Connection of arm 1(Installed in the left side ) 

The 

MOTOR+ 

terminal of the arm should be connected to the 

+MOTOR1

 terminal of the control board. The 

MOTOR-

 terminal should be connected to the 

MOTOR1- 

terminal of the control board. The 

DN

 terminal 

should be connected to the 

ULT1

 terminal of the control board. The 

COM

 terminal should be connected to 

the 

COM

 terminal of the control board. The 

UP

 terminal should be connected to the 

DLT1

 terminal of the 

control board. 

Содержание KNL502+

Страница 1: ......

Страница 2: ...e Opener s Base Plate 8 Step 6 Install the Gate Bracket 8 Step 7 Set the Limit Switches of the opener at left side 9 Step 8 Set the Limit Switches of the opener at right side 10 Mounting the Control B...

Страница 3: ...njury or death 1 READ AND FOLLOW ALL INSTRUCTIONS 2 Installation should be performed by a professional installer 3 Should electricity be required use a certified electrician only 4 Never let children...

Страница 4: ...2 Parts List...

Страница 5: ...essories Parts List Tools Needed Power Drill Tape Measure Level Hammer C Clamps Wire Strippers Phillips Screwdriver Hex Key Wrench 6mm Open End Wrenches 14 17 or Adjustable Wrenches An extra person sh...

Страница 6: ...orrectly and properly installed and in good smooth Features Soft start and soft stop Emergency release key in case of power failure Dual Single gate running mode Adjustable opening closing interval be...

Страница 7: ...ion of swing Gate opener We suggest that you become familiar with instructions and illustrations in this manual This will help insure that your installation is performed in an efficient and profession...

Страница 8: ...6 Step 2 Assemble Arms Step 3 Attach the Arms to Gate Opener Step 4 Determining the mounting positions...

Страница 9: ...7...

Страница 10: ...8 Step 5 Install the Opener s Base Plate Step 6 Install the Gate Bracket...

Страница 11: ...on Rotate the Bottom Collar until after hearing a click of Bottom Limit Switch s contact And then tighten the screw of Bottom Collar Set the left opened Limit Switch Loosen the screw of Top Collar Pus...

Страница 12: ...Rotate the Top Collar until after hearing a click of Top Limit Switch s contact And then tighten the screw of Top Collar Set the right opened Limit Switch Loosen the screw of Bottom Collar Push the r...

Страница 13: ...ontrol box use the deck screws not provided Ensure the control box is installed in a secure surface and at least 100 cm 40 inches above the ground to protect it from rain snow etc which probably cause...

Страница 14: ...s 1 5m length are provided Other cables are subject to site installation requirement and not provided CAUTION Make sure the cable outlet hole in the Control Box is always down during installation so a...

Страница 15: ...13 Connecting of the control board For Pull to Open...

Страница 16: ...nstalled in the Master Gate and ARM 2 is installed in the Slave Gate Alarm Lamp optional The red wire of the alarm lamp should be inserted into either LAMP 11 terminal the white wire into the other on...

Страница 17: ...RED wire of the external receiver should be connected into the 9 terminal Wired Keypad 24VDC optional The RED wire of the wired keypad should be connected into the 9 terminal The BLACK wire of the wi...

Страница 18: ...Interval between Master Slave Gate Setting The open interval can be adjusted by pressing the INC and DEC Buttons respectively The Digital Display will show 0 9 which indicates the interval time 0 mea...

Страница 19: ...is adjusted by pressing INC and DEC buttons respectively The Digital Display will show 1 9 which indicates the stall force levels 1 means the minimum force and 9 is the maximum force Each time you pr...

Страница 20: ...dicate Pb 10 Set the Period of Soft Start When the Digital Display indicates Pb the gate opener is ready for setting period of soft start You can press the INC or DEC button to set the period of soft...

Страница 21: ...ess and release the remote control the gate will move to the programmed closing position and stop While the gate is moving press and release the remote control the gate will stop moving immediately Th...

Страница 22: ...control board The MOTOR terminal should be connected to the MOTOR2 terminal of the control board The DN terminal should be connected to the DLT2 terminal of the control board The COM terminal should b...

Страница 23: ...AC input is connected Check if the fuse in control board is bad 2 Opener powers up but does not run Arm cable loose or disconnected Verify that all of the wires going to the arm are secure and that th...

Страница 24: ...motor cable is away from sources of electrical interference such as electric fences power lines etc 6 Gate opens closes or stops on its own Ensure that the key for manual release is in the lock positi...

Страница 25: ...23 Quick Setting Guide...

Страница 26: ...24...

Страница 27: ...25...

Страница 28: ...26...

Страница 29: ...27...

Отзывы: