background image

1. Always ensure the airline pressure is

correctly set to within the equipment's

safety limits 70-110psi (5-8bar).

2. Make sure the

air control valve 

is closed before 

connecting to

the air supply.

3. Select the most 

suitable nozzle for 

the job that you are 

doing and insert into 

the pick-up hose.

4. Insert the nozzle into 

the fluid and open 

the air control valve 

to commence 

extraction.

5. Close the control 

valve when extraction 

is finished.

6. To empty the reservoir, 

disconnect from the 

air supply, remove

the reservoir cap 

and pour into a 

suitable container 

for transport/storage.

Note:

Dispose of all waste 

fluids in accordance 

with the relevant

environmental health 

& safety quidelines

SAFETY GUIDELINES

This tool is easy and safe to use following the guidelines opposite.

l

Always wear safety goggles to protect your eyes from splashes

of fluids.

l

Always wear protective gloves when working with any type of

lubricant or fluid 

(used engine oil is carcinogenic)

.

l

Always wear ear protection as prolonged exposure may result in

damage to hearing.

l

Always clean out reservoir between uses - do not allow different

fluid types to mix.

2

3

KENNEDY

thoroughly recommends reading these instructions before using this

equipment, even if you have used one before. Reading these instructions carefully

and understanding them fully will enable you to perform tasks correctly and will

prevent injury to yourself or someone else. 

This equipment has been designed to drain brake fluid, waste oil from the sump of an engine via the dipstick

tube, drain and bleed brake and clutch fluids and to collect spillages of any non-corrosive fluid.

Technical Specifications

Model Number.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FEP010

Order Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KEN 540-4700K

Air Supply  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70-110psi (5-8bar)

Air Consumption  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180Ltr/min.

Vacuum (maximum)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500mm HG

Reservoir Capacity  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Ltr

Extraction Rate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5Ltr/min.

Air Inlet Size  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .