Страница 1: ...ervice and Assistance 20 For Sears warranty information or to contact a Sears Service Center call 1 800 4 MY HOME S_ 1 800 469 4663 IMPORTANT Read and follow all safety installation and operating instructions before first use of this product If you need SERVICE or PARTS for your Kenmore coin operated dryer When requesting service be ready to give the model number serial number located on a tag in ...

Страница 2: ...ned in washed in soaked in or spotted with gasoline dry cleaning solvents other flammable or explosive substances as they give off vapors that could ignite or explode Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Before the dryer is removed from service or discarded remove the door to the dry ing compartment Do not ...

Страница 3: ...installed in a mobile home or an area where local codes do not permit grounding through the neutral Fire Hazard Use a new UL approved 30 ampere power supply cord Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect r...

Страница 4: ...neutral wire white or center of power supply cord under the center screw of the terminal block 5 Connect the other two wires to outer terminal block screws Tighten all terminal block screws firmly 6 Tighten the strain relief screws 7 Insert tab of terminal block cover into slot of the dryer rear panel Secure cover with hold down screw NOTE If local codes do not permit the connection of a frame gro...

Страница 5: ... end of the wire over the terminal block screw The open side of the hook should face to the right Squeeze hook end of wire together to form a loop 5 Connect the other two wires to outer terminal block screws using the same method s described in step 4 Tighten all terminal block screws firmly 6 Tighten the strain relief screws 7 Insert tab of terminal block cover into slot of the dryer rear panel S...

Страница 6: ...green yellow Fire Hazard Use a new UL approved 30 ampere power supply cord Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical c...

Страница 7: ...al block cover 3 Attach a inch U L listed strain relief to the hole below terminal block opening Strain relief should have a tight fit with dryer cabinet and be in a horizontal position Put the power supply cord through the strain relief Terminal blockcover Hold down screw 4 Remove the center terminal block screw Remove the neutral grounding wire green yellow wire from external grounding screw Ext...

Страница 8: ...ust be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance SAVE THESE INSTRUCTIONS The dryer can be connected directly to fused disconnect or circuit breaker box with four wire flexible armored or non metallic sheathed copper cable with grounding ...

Страница 9: ...and vented it will not be covered under the warranty NOTE Service calls caused by improper venting will be paid for by the customer whether it was a paid installa tion or self installed For paid installation call the company that installed the vent for adjustment Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can resul...

Страница 10: ... plate on back of dryer Determining vent length The maximum length of the exhaust system depends upon The type of vent heavy or flexible metal The number of elbows 90 turns used To determine maximum vent length 1 See the Exhaust Hood Type chart that matches your type hood for the maximum vent lengths you can use Do not use vent runs longer than specified in exhaust vent length chart Exhaust system...

Страница 11: ...tructions and applicable local codes requirements NOTE Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets mobile homes or sleeping quarters Contact your local building inspector This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 f...

Страница 12: ...tall leveling legs Take two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it back on the cardboard corners Check leg for diamond marking This is how far the leg should go into the hole Start to screw legs into holes by hand A little liquid detergent applied to the legs will help lubricate them Use a 1 inc...

Страница 13: ...ng Failure to do so can result in death or electrical shock 3 If the dryer does not start remove the meter case service door 4 Push the ratchet arm towards the rear of the dryer until it stops then release 5 Replace the meter case service door Be sure the lock is located toward the rear of the case 6 Push the PUSH TO START button firmly Keep a record of all coin box key numbers A lost key can only...

Страница 14: ...de mechanism from meter case Line Up Notch to Clear Ratchet Tooth Hub Down with Narrow Blade Insert narrow screwdriver under nylon cam close to the timer shaft Lift cam gently off shaft Make sure that pressure is directed upward and the V notch clears the ratchet tooth 4 Replace new timing cam Be sure drive lug is in place Place cam hub down over timer shaft lining up flat on shaft with fiat of dr...

Страница 15: ...e supplied with Part 20 3006 in place 10 Plug in dryer or reconnect power NOTE Refer to the product information sheet provided with the coin box for additional information Opening dryer top Electrical Shock Hazard Disconnect power before servicing Replace all panels before operating Failure to do so can result in death or electrical shock 1 Unplug dryer or disconnect power 2 Open meter case access...

Страница 16: ...s will affect the performance of the dryer Cleaning should be done by a qualified service personnel Drying Time The following charts are provided to give a general guideline on typical full loads and suggested times for these loads TYPICAL FULL LOAD The following chart gives examples of typical full loads LOAD TYPE INCLUDES LOAD TYPE INCLUDES Mixed 2 sheets Heavy 4 pairs jeans Load 4 pillow cases ...

Страница 17: ...nt screen for lint Exhaust vent Check exhaust vent for lint blockage Power supply Check line fuses and switches Heat element Check for broken element wire Load Check for size and type of load Improperly grounded Check for control panel being grounded Drum will not rotate Drum belt Check for broken belt Be sure it is properly posi tioned on motor pulley Will not shut off Timer Check timer motor for...

Страница 18: ...thes bailing complaints Large garments sheets spreads bailing instead of tumbling Check to see if dryer is being overloaded Check drum speed 48 3 RPM If you need an additional parts list contact your nearest Sears Service Center or Parts Department Make sure to order by complete Model Number when ordering CHANGING VEND PRICE To change vend price detach and mail the lower portion to Customer Servic...

Страница 19: ...19 ...

Страница 20: ...nt parts you need Call 6 a m 11 p m CST 7 days a week PartsDirect 1 800 366 PART 1 800 366 7278 Para ordenar piezas con entrega a domicilio 1 800 659 7084 For the location of a Sears Service Center in your area Call 24 hours a day 7 days a week 1 800 488 1222 To purchase or inquire about a Sears Maintenance Agreement Call 7 a m 5 p m CST Monday Saturday 1 800 827 6655 SEARS HomeCentral ...