8-1-11 TEST Mode
1. The test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test mode is operated by pressing two buttons on the display panel.
3. While in the test mode, the function control button is not recognized, but the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
* Freezer Fan RPM Variable Check:
If the freezer fan is in operation when the WARMER REFRIGERATOR TEMP KEY & WARMER FREEZER TEMP KEY are
pressed for more than one second at the same time then the freezer fan RPM changes. (for example if high speed, to normal
speed or if normal speed, to high speed for 30 seconds)
After 30 seconds, it turns to its original RPM.
* Demonstration (Display) MODE:
1. To enter this mode, raise either the Refrigerator or Freezer temperature to its highest setting. Then, press that
Warmer key and hold for about 5 seconds..
2. The LED panels will display OFF, to indicate that the compressor, circulating fan , damper, and defrost heater are not
operating.
3. The Open Door Alarm and the Lamp Auto-Off feature will work normally and can be demonstrated.
4. To reset to normal operation, press and hold either Warmer Key for about 5 seconds.
- 29
-
MODE
MANIPULATION
CONTENTS
REMARKS
TEST1
TEST2
TEST3
Reset
Push ULTRA ICE
Maximum test time:
Maximum test time:
Key and COLDER key
of Freezer Temp. at the
Same time for 3 seconds
OR Push TEST switch (on
the main Board) Once.
Push ULTRA ICE
Key and COLDER Key
of Freezer Temp. at the
Same time for 3 seconds
In TEST MODE 1 OR
Push TEST switch Once in
TEST MODE 1
Push ULTRA ICE
Key and COLDER Key
of Freezer Temp. at the
Same time for 3 seconds
In TEST MODE 2 OR
Push TEST switch Once in
TEST MODE 2
Push ULTRA ICE
Key and COLDER Key
of Freezer Temp. at the
Same time for 3 seconds
In TEST MODE 3 OR
Push TEST switch Once in
TEST MODE 3
1) Continuous operation of the
compressor and the freezer fan
5 minutes
5 minutes
2) Stepping damper open
3) Defrosting heater OFF
4) Display LED all ON
1) Continuous operation of the
compressor and the freezer fan
2) Stepping damper close
3) Defrosting heater OFF
4) Display LED shows 2
1) Compressor and the freezer fan
OFF
2) Stepping damper close
3) Defrosting heater ON
4) Diplay LED shows 3
Reset if the
temperature of the
defrosting sensor is
8°C (46°F)or more.
The compressor will
start after a 7-minute delay.