6. TROUBLESHOOTING
- 1
2
-
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
5
4
5
5
1
4
3
YES
YES
The range of resistance is between 1~50
Ω
(OK)
Not open
4.5~9
Ω
Open
Open or short
Open or short
YES
YES
NO
NO
Power Source.
No Voltage.
(Reated Voltage
±10%)?
Replace OLP.
Reconnect.
Replace
PTC-Starter.
Replace OLP.
Did
compressor
start?
Compressor
is OK
Replace the
compressor
Check connection
condition.
OLP disconnected?
Advise customer that
power supply needs to be
checked by an electrician.
Replace
Compressor.
Supply
voltage rating
with ±10%.
Applied voltage isn't
in range of Rating
Voltage ±10%.
Remove PTC-Starter
from Compressor and
measure voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.
Check resistance
between M-C, S-C and
M-S in Motor
Compressor.
Check resistance of
two terminals in
PTC-Starter.
Check resistance of two
terminals in OLP.
Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).
Check
resistance of
Motor
Compressor.
Check
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
NO
Содержание 795.75082.401
Страница 10: ...GY GRIS GRAY Best Best dispenser 5 CIRCUIT DIAGRAM 10 ...
Страница 11: ...GY GRIS GRAY Good Better 11 ...
Страница 40: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 40 ...
Страница 41: ...8 5 2 Replacement Parts List 41 ...
Страница 42: ...8 5 3 PWB Assembly Display And Parts List 42 ...
Страница 43: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 43 G5S 1A RY5 ...
Страница 44: ... 44 ...
Страница 66: ...LAST EDITION Oct 31 2005 ...