B3. LED blinks five times, then repeats (Locked Piston)
Protection Logic
Protection Logic
Blink Blink Blink Blink Blink OFF
Protection
logic
Check B
Blink 5 times
(Lock Piston Trip) Check B3
Compressor
Doesn’t work
Repeat
Check Procedure
Reset
Power
Compressor
Doesn’t work
N
Y
Replace
Compressor
Hi side
restriction
N
Y
Sealed
system
Repair
- Purpose: To detect locked piston
- Cause: Lack of oil to the cylinder, cylinder or piston damaged and or restricted discharge.
A Locked Piston can also be caused by foreign materials inside the compressor.
- Logic: Compressor is forced off and tries to restart within 2.5 minutes.
B4. LED blinks six times, then repeats (Current Trip)
Blink
Blink
Blink Blink Blink Blink
OFF
Protection
logic
Check B
Blink 6 time
(Current Trip) Check B4
Compressor
Intermittently
works
Y
Capacitor
Spec.
Check C2
Compressor
Damage
Check C3
Replace
Capacitor
Replace
Compressor
NG
NG
Reset
Power
Y
Current trip
Occur?
Y
Repeat
Check Procedure
IPM
Check B5
Y
Replace
Driver PCB
NG
N
Y
N
Cycle
Check E
Y
Fix
Cycle
- Purpose: Prevent over-current (overload protect)
- Cause: Ambient temperature is high (over 43°C) and/or refrigerator’s condenser air movement is restricted.
- Condenser Fan is stopped, restricted discharge line, compressor is damaged, or IPM device is defective.
- Logic: Compressor is forced off and tries to restart after 6 minutes.
Содержание 795.74092.41 Series
Страница 7: ... 7 ...
Страница 23: ... 23 5 CIRCUIT DIAGRAM ...
Страница 24: ... 24 6 TROUBLESHOOTING ...
Страница 25: ... 25 ...
Страница 27: ... 27 7 3 Sub PCB P N EBR76468402 ...
Страница 103: ...625A 623B 616J 623B 616J 603C S04 627B S04 627A S04 603B 619A 617A 616G VALVE WATER TUBE PARTS ...
Страница 105: ...CASE PARTS ...
Страница 106: ...CASE PARTS ...
Страница 110: ...DOOR PARTS ...
Страница 111: ...DISPENSER PARTS 405A 278D 402C 276B 275A 276A 276I 501A 279A 278B 500J 276J 267B 279J 281A ...
Страница 112: ...ICE MAKER ICE BIN PARTS 600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J 607A ...